Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
Returns 2 data bytes (16-bit value):
• Bytes 0 and 1 = Power limit
Set this value with command
4
.
170
report user reflected
power limit
Reports the user reflected power limit in
watts. The user reflected power limit affects
all regulation modes. The unit retains the user
reflected power limit as long as power is
applied. You cannot change the user reflected
power limit while the unit is on. Valid values
are from the specified reflected power
minimum to the specified reflected power
maximum.
Returns 2 data bytes (16-bit value):
• Bytes 0 and 1 = User reflected power
limit
Set this value with command
5
.
0
2
171
report DC bias
external feedback
limit
Reports the DC bias value when operating in
external (DC bias) regulation mode.
Send 0 data bytes to return external feedback
limit in volts or send 1 data byte to return User
External Feedback Limit, User External
Feedback Limit Max, or Max User setpoint, in
volts.
Send 0 data bytes:
• Returns 2 data bytes:
◦ Bytes 0 and 1 = User external feedback
limit in volts
Send 1 data byte (8-bit value):
• 0 = Returns user external feedback limit
in volts
• 1 = Returns user external feedback limit
maximum in volts
• 2 = Returns maximum user setpoint in
volts
Returns 2 data bytes = Selected value in volts
Set this value with command
6
.
0 or 1
2