Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
Byte 0 =
Subcommand
5
Set frequency step start
6
Set gamma threshold high
7
Set gamma threshold low
8
Set maximum tuning count
22
Set tuning step time
23
Set tuning gain delay
50
Set DC bias operating mode
51
Set fixed frequency memory
mode
118
set frequency step
minimum (NV)
(subcommand 1)
Sets the frequency tuning frequency step
minimum size in Hz. Valid values must be less
than the frequency step maximum and greater
than 200 Hz.
Send 6 data bytes.
• Bytes 0 and 1 = 1 (set frequency step
minimum)
• Bytes 2 through 5 = Frequency step
minimum
Command
248
reports this value; B0 = 1.
6
1
118
set frequency step
maximum (NV)
(subcommand 2)
Sets the frequency tuning frequency step
maximum size in Hz. Valid values must be
greater than the frequency step minimum and
less than 100,000 Hz.
Send 6 data bytes.
• Bytes 0 and 1 = 2 (set frequency step
maximum)
• Bytes 2 through 5 = Frequency step
maximum
Command
248
reports this value; B0 = 2.
6
1
118
set step up gain
(NV)
(subcommand 3)
Sets the magnitude of frequency step increase
when the error is decreasing. A value of
n
sets
the gain to 2
n
. The default value is 2 (gain =
2
n
= 2
2
= 4). Valid values are 1 to 7.
4
1
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑34