Table 4‑10. AE Host commands (Continued)
Command
Description
Data Bytes
Sent
Data
Bytes
Returned
Set this value with command
44
.
145
report maximum
tuning frequency
Reports the maximum frequency that the
generator uses for automatic tuning. The
maximum tuning frequency must be within
the unit’s factory-set frequency range. The
unit stores this parameter in nonvolatile
memory.
Send 0 data bytes to return frequency in kHz,
or send 1 data byte to return frequency in kHz
or Hz.
Send 0 data bytes:
• Returns 4 data bytes = Frequency in kHz
Send 1 data byte:
• Byte 0 = Frequency in kHz or Hz
◦ 0 = Returns frequency in kHz
◦ 1 = Returns frequency in Hz
Returns 4 data bytes = Frequency in kHz or
Hz
Set this value with command
45
.
0 or 1
4
146
report tuning start
frequency
Reports the frequency in kHz at which the
generator starts automatic tuning. The tuning
start frequency must be greater than or equal
to the current minimum tuning frequency and
less than or equal to the current maximum
tuning frequency. The unit stores this
parameter in nonvolatile memory.
Send 0 or 1 data bytes.
Send 0 data bytes to return frequency in kHz,
or send 1 data byte to return frequency in kHz
or Hz.
Send 0 data bytes:
• Returns 4 data bytes = Frequency in kHz.
Send 1 data byte:
• Byte 0 = Frequency in kHz or Hz
0 or 1
4
Advanced Energy
®
Paramount
®
MF 2 kW Generator
57020114-00E
Communication Controls
4‑42