SmartRG Inc., an ADTRAN company. All Rights Reserved. © 2020
140
4. To modify the system log settings:
a. Click
Configure System Log
. The System Log - Configuration page appears.
b. Modify the settings as needed, using the information provided in the following table.
Action
Description
Log
Select to turn logging off or on. The default is
Disable
.
Logging Level
Select
Error
unless actively troubleshooting a situation with a subscriber for which increased log
detail is required. Options are
Emergency
,
Alert
,
Critical
,
Error
,
Notice
,
Warning
,
Informational
,
and
Debugging
. The options are listed in top-down order. The default is
Debugging
.
Display Level
Select
Error
unless actively troubleshooting a situation with a subscriber for which increased detail
is required. This field has the same options as the
Logging Level
field. The default is
Error
.
Mode
Select where log events will be sent.
To send logs to the specified IP address and UDP port of a remote syslog server, select
Remote
or
Both
.
To record events in the local memory of your SmartRG gateway, select
Local
or
Both
.
c. Click
Apply/Save
to save your changes.