A1-User’s Manual
63
8.1.8
Standard AO (FM, AMI)
No.
Name
Change during
operation
Range
Default
Page
12.01
AO (FM, AMI) forced selection
X
0x00 to 0xFF
0x00
101
12.02
AO1 (FM) actual value
-
0.0 to 100.0 [%]
-
101
12.03
AO1 (FM) source
-
0. Out Frequency
1. Out Ampere
2. Out Voltage
3. Out Power
4. Out Torque
5. Modbus communication
6.
DC link Voltage
0
101
12.04
AO1 (FM) forced value
O
0.0 to 100.0 [%]
0.00 %
102
12.05
AO1 (FM) filter time
O
0 to 30000 [ms]
100 ms
102
12.06
AO1 (FM) source min
X
0.0 to 100.0 [%]
0.00 %
103
12.07
AO1 (FM) source max
X
0.0 to 100.0 [%]
100.0 %
103
12.08
AO1 (FM) out at AO1 min
X
0.0 to 100.0 [%]
0.00 %
104
12.09
AO1 (FM) out at AO1 max
X
0.0 to 100.0 [%]
100.0 %
104
12.10
AO2 (AMI) actual value
-
0.0 to 100.0 [%]
-
104
12.11
AO2 (AMI) source
-
0. Out Frequency
1. Out Ampere
2. Out Voltage
3. Out Power
4. Out Torque
5. Modbus communication
6.
DC link Voltage
1
104
12.12
AO2 (AMI) forced value
O
0.0 to 100.0 [%]
0.00 %
104
12.13
AO2 (AMI) filter time
O
0 to 30000 [ms]
100 ms
104
12.14
AO2 (AMI) source min
X
0.0 to 100.0 [%]
0.00 %
104
12.15
AO2 (AMI) source max
X
0.0 to 100.0 [%]
100.0 %
104
12.16
AO2 (AMI) out at AO2 min
X
0.0 to 100.0 [%]
0.00 %
104
12.17
AO2 (AMI) out at AO2 max
X
0.0 to 100.0 [%]
100.0 %
104
12.18
AO2 (AMI) Initial Current
X
0.00 to 0.60[mA]
0.40mA
105