ADTECH9 Series CNC Maintenance Manual
- 175 -
Note
: To set tapping closed-loop adjusting parameters
(proportional-derivative-integral adjusting parameters) to use default
values
028
Tapping adjusting parameter Ki
Range :
Unit
:
None
Authority
:
Operation admin or higher
Default :
0.0
Effective
time
:
Instant
Note
: To set tapping closed-loop adjusting parameters
(proportional-derivative-integral adjusting parameters) to use default
values
029
Tapping adjusting parameter Kd
Range :
Unit
:
None
Authority
:
Operation admin or higher
Default :
0.6
Effective
time
:
Instant
Note
: To set tapping closed-loop adjusting parameters
(proportional-derivative-integral adjusting parameters) to use default
values
030
Filter coefficient of tapping adjusting parameter Kd
Range :
Unit
:
None
Authority
:
Operation admin or higher
Default :
500.0
Effective
time
:
Instant
Note
:
Default value is generally used to set tapping closed loop adjustment
parameters
Summary of Contents for CNC9 Series
Page 1: ...ADTECH 9 Series CNC Maintenance Manual ...
Page 18: ...ADTECH9 Series CNC Maintenance Manual 13 2 2ADTCNC99 and 98 series system LCD keypad ...
Page 19: ...ADTECH9 Series CNC Maintenance Manual 14 ...
Page 45: ...ADTECH9 Series CNC Maintenance Manual 40 ...
Page 216: ...ADTECH9 Series CNC Maintenance Manual 211 11 3 2 Power connection diagram ...
Page 217: ...ADTECH9 Series CNC Maintenance Manual 212 11 3 3 Servo driver connection diagram ...
Page 218: ...ADTECH9 Series CNC Maintenance Manual 213 11 3 4 Step connection diagram ...
Page 219: ...ADTECH9 Series CNC Maintenance Manual 214 11 3 5 IO electrical connection diagram ...
Page 220: ...ADTECH9 Series CNC Maintenance Manual 215 ...