ADTECH9 Series CNC Maintenance Manual
- 118 -
Output signal stops keeping for the seconds specified by P1.023
(reverse phase).
Output signal follows the hertz specified by P1.024 in working state,
and used for oil supply devices. If it is set to 0, the system will keep low
output level.
025
Back Home Mode Configuration (BIT)
Range :
Unit
:
Authority
:
Operation admin or higher
Default
:
Z – XYABC
Effective
time
:
Instant
Note
:
Set the zero sequence of each axis; up to three sections can be set.
026
Arc speed for Radii
027
Arc speed for Speed
Range :
Unit
:
Coefficient
Authority
:
Operation admin or higher
Default :
50,
100
Effective
time
:
Instant
Note
:
Used to restrict the arc processing speed automatically. This parameter is
valid in pretreatment mode.
The bigger the radius coefficient is, the lower the arc speed is.
The bigger the acceleration coefficient is, the higher the arc speed is.
028
Pretreatment Code Setting
Range :
100~5000
Unit
:
Instruction
line
Authority
:
Operation admin or higher
Default :
500
Effective
time
:
Instant
Note
:
Set the pre-reading instruction lines; if the pretreatment processing
Summary of Contents for CNC9 Series
Page 1: ...ADTECH 9 Series CNC Maintenance Manual ...
Page 18: ...ADTECH9 Series CNC Maintenance Manual 13 2 2ADTCNC99 and 98 series system LCD keypad ...
Page 19: ...ADTECH9 Series CNC Maintenance Manual 14 ...
Page 45: ...ADTECH9 Series CNC Maintenance Manual 40 ...
Page 216: ...ADTECH9 Series CNC Maintenance Manual 211 11 3 2 Power connection diagram ...
Page 217: ...ADTECH9 Series CNC Maintenance Manual 212 11 3 3 Servo driver connection diagram ...
Page 218: ...ADTECH9 Series CNC Maintenance Manual 213 11 3 4 Step connection diagram ...
Page 219: ...ADTECH9 Series CNC Maintenance Manual 214 11 3 5 IO electrical connection diagram ...
Page 220: ...ADTECH9 Series CNC Maintenance Manual 215 ...