ADTECH9 Series CNC Maintenance Manual
- 117 -
Range :
0~1
Unit
:
None
Authority
:
Operation admin or higher
Default :
0
Effective
time
:
Instant
Note
:
Control mode corresponding to spindle S code (frequency conversion
mode)
0 : Analog output
1: Section speed regulation (4-digit code determined by output port
configured by spindle parameters P6.014 ~ P4.017), as below:
P6.014------S0
P4.015------S1
P4.016------S2
P4.017------S3
In analog output mode, the analog voltage is:
V
=
S/MaxRPM
S is the rotation set by the user, and MaxRPM is the maximum rotation
of spindle set by the parameter (P4.017);
In switching quantity mode, constitute block 0-15 according to
four-digit code to output; S code value is restricted to 0-15;
022
Lubricant Pressure Open(min)
023
Lubricant Pressure Keep(sec)
024
Lubricant Pressure Out Freq(Hz)
Range :
Unit
:
Authority
:
Operation admin or higher
Default :
0
Effective time
Note
:
:
Instant
Set the schedule start and holding time of the automatic oil pump of the
system
Schedule open setting is that the settings of P6.045 oil pump output
ports when the timing reaches specified value after the system starts and
times.
Summary of Contents for CNC9 Series
Page 1: ...ADTECH 9 Series CNC Maintenance Manual ...
Page 18: ...ADTECH9 Series CNC Maintenance Manual 13 2 2ADTCNC99 and 98 series system LCD keypad ...
Page 19: ...ADTECH9 Series CNC Maintenance Manual 14 ...
Page 45: ...ADTECH9 Series CNC Maintenance Manual 40 ...
Page 216: ...ADTECH9 Series CNC Maintenance Manual 211 11 3 2 Power connection diagram ...
Page 217: ...ADTECH9 Series CNC Maintenance Manual 212 11 3 3 Servo driver connection diagram ...
Page 218: ...ADTECH9 Series CNC Maintenance Manual 213 11 3 4 Step connection diagram ...
Page 219: ...ADTECH9 Series CNC Maintenance Manual 214 11 3 5 IO electrical connection diagram ...
Page 220: ...ADTECH9 Series CNC Maintenance Manual 215 ...