ADTECH9 Series CNC Maintenance Manual
- 130 -
Unit
:
Authority
:
Operation
admin
Default :
0
Effective
time
:
Instant
Note
:
To set the IP address to access the remote Modbus slave when the system
is used as a Modbus master
079
Modbus master timeout (ms)
Range :
0~1000
Unit
:
Authority
:
Operation
admin
Default :
0
Effective
time
:
Instant
Note
:
To set the communication timeout to access the remote Modbus slave
when the system is used as a Modbus master
080
Modbus master retransmission times
Range :
0~100
Unit
:
Authority
:
Operation
admin
Default :
10
Effective
time
:
Instant
Note
:
To set the communication retransmission times to access the remote
Modbus slave when the system is used as a Modbus master
081
UART3 serial port baud rate
Range :
9600~115200
Unit
:
Authority
:
Operation
admin
Default :
115200
Effective
time
:
Instant
Note
:
To set the communication baud rate of UART3 serial port (RS485)
082
Local IP address 2
Range :
Unit
:
Summary of Contents for CNC9 Series
Page 1: ...ADTECH 9 Series CNC Maintenance Manual ...
Page 18: ...ADTECH9 Series CNC Maintenance Manual 13 2 2ADTCNC99 and 98 series system LCD keypad ...
Page 19: ...ADTECH9 Series CNC Maintenance Manual 14 ...
Page 45: ...ADTECH9 Series CNC Maintenance Manual 40 ...
Page 216: ...ADTECH9 Series CNC Maintenance Manual 211 11 3 2 Power connection diagram ...
Page 217: ...ADTECH9 Series CNC Maintenance Manual 212 11 3 3 Servo driver connection diagram ...
Page 218: ...ADTECH9 Series CNC Maintenance Manual 213 11 3 4 Step connection diagram ...
Page 219: ...ADTECH9 Series CNC Maintenance Manual 214 11 3 5 IO electrical connection diagram ...
Page 220: ...ADTECH9 Series CNC Maintenance Manual 215 ...