Group Cable type
Wiring Requirement
A
AC power cord
Bundle the cables of group A separately from group B
and C, keep at least 10cm clearance, or make
electromagnetic shielding for group A
AC coil
AC contactor
B
AC coil (24VDC)
Bundle the cables of group B separately from group A or
shield group B; group B and group C should be as far as
possible
DC relay (24VDC)
Cable between system and strong current cabinet
Cable between system and machine tool
C
Cable between system and machine tool
Bundle the cables of group C separately from group A,
or shield group C; keep at least 10cm clearance between
group C and group B and use twisted pair
Position feedback cable
Position encoder cable
Handwheel cable
Other cables for shielding
11.2
Interface Definition
12.2.1.
Motor driver control interface
Four driver interfaces are available (XS1.. XS4, XS8 (note: CNC9650) of 96 series or XS1…XS4, XS5, XS6 of
99 series), and they have the same definition, as shown below:
96 series pulse interface
99 series pulse interface
Summary of Contents for CNC9 Series
Page 1: ...ADTECH 9 Series CNC Maintenance Manual ...
Page 18: ...ADTECH9 Series CNC Maintenance Manual 13 2 2ADTCNC99 and 98 series system LCD keypad ...
Page 19: ...ADTECH9 Series CNC Maintenance Manual 14 ...
Page 45: ...ADTECH9 Series CNC Maintenance Manual 40 ...
Page 216: ...ADTECH9 Series CNC Maintenance Manual 211 11 3 2 Power connection diagram ...
Page 217: ...ADTECH9 Series CNC Maintenance Manual 212 11 3 3 Servo driver connection diagram ...
Page 218: ...ADTECH9 Series CNC Maintenance Manual 213 11 3 4 Step connection diagram ...
Page 219: ...ADTECH9 Series CNC Maintenance Manual 214 11 3 5 IO electrical connection diagram ...
Page 220: ...ADTECH9 Series CNC Maintenance Manual 215 ...