Feature
Parameter
Description
Hard Disk
Hard Disk
2 built-in SATA port supports 2 HDD up to 8TB
Record and
Playback
Record Mode
Manual, Motion Detection, Schedule and Alarm recording
Priority: Manual > Alarm > Motion Detection > Schedule
Playback Repeat When hard disk is full, system can overwrite previous video file
Record Search
Various search engines such as time, type and channel.
Playback Mode
Various fast play, slow play speeds, manual frame by frame playback
and reverse play mode
File Switch
•
Can switch to previous or next file or any file in current play list
•
Can switch to file on other channel of the same time
•
Supports file continuous play: when the current file ends, plays the
next file on the current channel
Multi-channel
Playback
4 Channel
1-channel,
4-channel
8 Channel
1-channel,
4-channel,
8-channel
16 Channel
1-channel, 4-channel,
8-channel, 9-channel
and 16-channel
Window Zoom
Switch between self-adaptive screen/full screen during playback
Partial
Enlargement
When in one-window full-screen playback mode, you can select any
zone to activate partial enlargement function.
Backup
Function
Backup Mode
Supports peripheral USB backup device (flash drive, portable disk, etc.)
Supports eSATA device backup
Supports network download and backup
Network
Function
Network Control View monitor channel remotely
NVR configuration through client end and web browser
Upgrade via client or browser to initiate remote maintenance
View alarm information such as external alarm, motion detection and
video loss via client
Supports network PTZ lens control
Supports file download backup and playback
Network alarm input and output
Motion
Detection and
Alarm
Motion
Detection
•
Zone setup: supports 396 (PAL 22
x
18, NTSC 22
x
15) detect zones
•
Various sensitivity levels
•
Alarm can activate record, external alarm or screen message prompt
Video Loss
Alarm can activate screen message prompt
External Alarm
Supports record activation or external alarm activation or screen
message in specified period
Manual Alarm
Control
•
Enable or disable alarm input channel
•
Supports analog alarm signal to specific alarm output channel
Alarm Input
4 Channel
4-ch alarm input–
select the alarm type:
normally open or
normally closed
8 Channel
8-ch alarm input–
select the alarm type:
normally open or
normally closed
16 Channel
16-ch alarm input–
select the alarm type:
normally open or
normally closed
Alarm Output
3 channel relay output, one of which can c12VDC output
Alarm Relay
30VDC, 1A; 125VAC, 0.5A (Alarm activation)