ADOS S.R.L. Buccinasco (MI)
417-MTA200I1
Rev. 9
Page 39 of 77
A200E Registers list
Register 0 is a special coded register (see details).
Weigh values (gross, net, tare and set points) are coded on two consecutive registers as 2’s
complement binary value.
Configuration parameters are coded as explained in “Configuration” paragraph.
Registers marked as “
R
” are read only, those marked as “
R/W
” are read-write
Register
Number
Function Type
0
Status word
R
1
Batch status
R
2
Batch timer
R
3
Aux relays status (from relay 4 to relay 11)
R
4-5
Gross weight value
R
6-7
Load tare value/peak value
R
8-9
Unload tare value (Batch version) Tare 1 (Threshold mode)
R
10-11
Dosed component net value(Batch version) Weight acquired
(Threshold mode)
R
12-13
Totalizer first load component
R
14-15
Totalizer second load component
R
16-17
Totalizer third load component
R
18-19
Totalizer unload component
R
20
Graduation
R/W
21
Sensitivity
R/W
22
decimal point position
R/W
23
averaging coefficient
R/W
24
AZM limit
R/W
25
Motion
R/W
26
Zero tracking
R/W
27
Operating mode
R/W
28
Baud rate
R/W
29
Primary serial port
R/W
30
485 address
R/W
31
Input 1 function
R/W
32
Input 2 function
R/W
33
Input 3 function
R/W
34
Relay 1 function
R/W
35-36
Relay 1 Set point
R/W
37
Relay 2 function
R/W
38-39
Relay 2 Set point
R/W
40
Relay 3 function
R/W
41-42
Relay 3 Set point
R/W