113546 - 2
www.adclaundry.com
29
Coin Programming ____________________
Enter Programming Mode By Placing
The Programming Switch On The Phase 7 Board Up
While No Cycle Is In Progress.
“Program Mode” Will Then Be Displayed.
Navigating Within The Programming Mode:
“Med” Key To Enter A Program Location.
“Hi-temp” / “Lo-temp” Keys Increase / Decrease
Program Location.
“Pause” Key Rejects Entry And Moves To Next
Program Location.
Changing A Parameter Value:
With Parameter Value Displayed Pressing “Lo Temp”
Or “High Temp” Changes The Parameter Value.
“Med” Key Must Be Pressed To Accept A New Parameter.
150F (66C) Maximum Temperature on Axial Models
Typical Programming Example:
Change a single coin acceptor from factory setting to yield 20
minutes for $.50, $.50 as the minimum amount to start, and
no differential in regard to temperature key selection.
Settings: Time for Amt to Start (PL03, PL04, PL05) 20
Left Coin Denomination (PL06) ............. $ .25
Amount to Start (PL06) .......................... $ .50
Clearing Coin Credit:
NO CYCLE IN PROGRESS AND PROGRAM SWITCH
DOWN.
Hold PAUSE while pressing HI 3 times, LO twice, and MED
once.
“Clear Credit?” will appear. Press any key to complete.
Accessing and Clearing Coin Vault Total
Enter program mode by switching program switch (up) while
no cycle is in progress.
Press HI – “Coin Vault total is $XXX” will appear.
Press HI – “Clear Coin Vault Total?” will appear.
Press MED to clear this amount or PAUSE to leave as is.
Hot Keys:
In the Coin Mode Hot Keys are enabled while in a cycle by
placing the program switch in the program (up) position.
In Free Mode Hot Keys are always enabled.
HI – Remaining credit – coin mode / remaining time – free
mode.
MED – Temps – Exhaust / left, S.A.F.E. / right, Axial / middle
(Axial dryer)
LO – Tumbler RPM
S.A.F.E. TEST: Switch to program mode. Press and hold the
“Pause” key until prompted to press MED to open the water.
L.C.D. Operating Messages
When Display Reads “Out of Order”
Pressing LO displays one of the causes listed below.
MODEL FAULT – Wrong model selected at PL01/3rd position.
SAIL SWITCH CLOSED – Sail switch closed before starting.
SAIL SWITCH OPEN – Sail switch failed to close after starting.
BURNER HI-LIMIT – Oven thermostat switch has opened.
EXHAUST HI-LIMIT – Tumbler thermostat switch has opened.
BURNER CONTROL – No gas valve signal – Bad DSI unit.
IGNITION FAULT – No flame ignition detected thru all retries.
FLAME FAULT – Flame detected at ignition but failed later.
CLEAN LINT – Due to failure to clean out lint.
CHECK CONTROL BOARD FUSE #2 – 2 on Phase 7 board
is open.
EXHAUST PROBE FAULT / AXIAL – Indicated probe has
failed.
ROTATION SENSOR – Rotation sensor or tumbler drive has
failed.
EXHAUST HI-TEMP – Overheating condition has occurred.
BURNER PURGE FAULT – Gas return signal before heat
output.
“S.A.F.E. System Disabled”
In Coin Mode hold “Pause” and “LO” keys down together.
OPEN / SHORTED THERMISTOR – Probe or probe circuit
bad.
OPEN / SHORTED WATER VALVE – Water valve or circuit
bad.
WATER NOT CONNECTED – No water pressure at sol. valve.
“S.A.F.E. System (was) Activated”
Indicates the S.A.F.E. system is active or was active because
a fire was detected. The buzzer sounds at a fast pace while
the system is active.
FUNCTION
SAMPLE AXIAL
DRYER SETTINGS
PL01
CONTROL
SETTINGS
Language
English
Temperature Scale
F
Buzzer Mode
Buzz
Beep Count 1 to 9 Beeps
2
Dry Mode
Coin Dry Mode
Pause Time 1 to 3 Minutes
1 Minute
Ready Prompt
Rdy Inst Amt to Start
PL02
MACHINE
SETTINGS
Model
Gas Dual Motors
Rotation Sensor
On
Lint Clean 1 to 10 Hours
2
Axial Thermistor Input
On
Axial Thermistor Setpoint
180F 82C
PL03
HI KEY
SETTINGS
Time for Amt to Start 1-99M
10 Minutes
Time for Top Off 1 to 99 M
10 Minutes
Dry Temp 100 to 190F*
150F 66C
Cool Time 0 to 9 Minutes
2
PL04
MED KEY
SETTINGS
Time for Amt to Start 1-99M
12 Minutes
Time for Top Off 1 to 99 M
12 Minutes
Dry Temp 100 to 190F*
140F 60C
Cool Time 0 to 9 Minutes
2
PL05
LO KEY
SETTINGS
Time for Amt to Start 1-99M
14 Minutes
Time for Top Off 1 to 99 M
14 Minutes
Dry Temp 100 to 190F*
120F 49C
Cool Time 0 to 9 Minutes
2
PL06
VENDING
ITEMS
Currency Symbol
USD ($)
Vending Mode
Accumulative Time
Vending Safeguard
Bad Coin Reset
Left Coin Den .05 to 25.00
0.25
Right Coin Den .05 to 25.00
0.10
Amount to Start .05 to 25.00
0.25
Amount for Top Off
0.25
PL07
No Faults / Faults
Summary of Contents for AD120i