ADC AD120i Installation & Operator'S Manual Download Page 24

24

American Dryer Corp.

113546 - 2

Preoperational Instructions __________

IMPORTANT:

 For more detailed information regarding the

microprocessor controller (computer), refer to the
microprocessor user’s manual included with the dryer.

Coin Models

Microprocessor Controller (Computer)

When the microprocessor controller (computer) is in the ready
state, the L.C.D. screen will display “Ready, Insert $XX.XX
(amount) to Start”.
Insert coin(s).  Once the correct “Amount to Start” has been
inserted, the L.C.D. will display “Select Temperature”.
Select temperature by pressing “HI,” “MED,” or “LO.”  The
cycle will start and the L.C.D. will display the Dry Cycle selected
and the remaining time.
The dryer will continue through the drying and cooling cycles,
until the vended time has expired.

NOTE: 

To stop the dryer, open main door.  Continuation of

the cycle will resume only after the door has been closed
and any one of the three temperature selections is pressed.

Non-Coin Models

Microprocessor Controller (Computer)

The L.E.D. display reads “READY” (no cycle in progress).
Press the letter on the keypad corresponding to the cycle
desired (e.g. key “D”).
The dryer will then start (i.e. blower, tumbler, and heat).
The L.E.D. display will read MANUAL DRYING CYCLE D,
___MIN REMAIN.

NOTE: 

The dryer can be stopped at any time by pressing

the “STOP/CLEAR” key, at this time the dryer will go into a
cycle pause.  If the “STOP/CLEAR” key is pressed again at
this point, the cycle that was in progress will be cancelled
and returned to the “READY” state.

When the programmed drying time has expired, the non-coin
microprocessor controller (computer) will proceed into the Cool
Down Cycle.
Once the Cool Down Cycle begins at the end of the heat cycle,
the L.E.D. display will read COOL DOWN TEMP ___/___
MINUTES remaining.  At the end of the heat cycle, the dryer
will shut off the heat and continue the fan and tumbler until
the Cool Down Time or temperature is reached.

Shutdown Instructions ________________

If the dryer is to be shutdown (taken out of service) for a period
of time, the following must be performed:
Discontinue power to the dryer either at the external disconnect
switch or the circuit breaker.
Discontinue the heat supply:
Gas Models – Discontinue the gas supply.
Shut off external gas supply shutoff valve.
Shut off internal gas supply shutoff valve located in the gas
valve burner area.

Service / Parts Information ___________

Service

Service must be performed by a qualified trained technician.
If service is required, contact the reseller from whom the
equipment was purchased.  If the reseller cannot be contacted
or is unknown, contact the Service Department for a reseller
in your area.

NOTE: 

When contacting the Service Department, be sure to

give them the correct model number and serial number so
that your inquiry is handled in an expeditious manner.

Parts

Replacement parts should be purchased from the reseller from
whom the equipment was purchased.  If the reseller cannot
be contacted or is unknown, contact the Parts Department for
a reseller in your area.  Parts may also be purchased directly
from the factory by calling the Parts Department at +1 (508)
678-9000 or you may FAX in your order at +1 (508) 678-9447.

NOTE: 

When ordering replacement parts from the reseller

or the manufacturer, be sure to give them the correct model
number and serial number so that your parts order can be
processed in an expeditious manner.

Warranty Information _________________

Returning Warranty Cards

Before any dryer leaves the factory test area, a warranty card
is placed on the inside of the main door glass.  These warranty
cards are intended to serve the customer where we record
the individual installation date and warranty information to
better serve you should you file a warranty claim.
If a warranty card did not come with your dryer, contact the
Warranty Department or the Service Department at +1 (508)
678-9000.

IMPORTANT: 

A separate warranty card must be completed

and returned for each individual dryer.

NOTE: 

Be sure to include the installation date when

returning the warranty card(s).

Warranty

For a copy of the commercial warranty covering your particular
dryer(s), contact the reseller from whom you purchased the
equipment and request a dryer warranty form.  If the reseller
cannot be contacted or is unknown, warranty information can
be obtained from the factory by contacting the Warranty
Department at +1 (508) 678-9000.

NOTE: 

Whenever contacting the factory for warranty

information, be sure to have the dryer’s model number and
serial number available so that your inquiry can be handled
in an expeditious manner.

Returning Warranty Parts

All dryer or parts warranty claims or inquiries should be
addressed to the Warranty Parts Department.  To expedite
processing, the following procedures must be followed:
No parts are to be returned without prior written authorization
(R.M.A.) from the factory.

NOTE: 

An R.M.A. is valid for only 30 days from date of

issue.

Summary of Contents for AD120i

Page 1: ...isin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incendies L installation et l entretien doivent tre assur s par un installateur ou...

Page 2: ...ur order is processed accurately and promptly These instructions are only valid if the following country code is on the appliance If this code is not present on the appliance it is necessary to refer...

Page 3: ...he following installation instructions apply Installations and repairs must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the State of Massachusetts...

Page 4: ...terials Drying in a heated tumbler may damage plastics or rubber and also may be a fire hazard The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produc...

Page 5: ..._ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ _________...

Page 6: ...IRBORNE SOUND LEVEL 69 dB A DRYERS PER 20 40 CONTAINER 4 9 DRYERS PER 48 53 TRUCK 10 12 VOLTAGE AVAILABLE 208 480V 1 3 2 3 4w 50 60 Hz APPROXIMATE NET WEIGHT 1 440 lb 653 17 kg APPROXIMATE SHIPPING WE...

Page 7: ...claundry com 7 NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation Specifications ______________________________________________________...

Page 8: ...tible construction as noted in this manual refer to Dryer Enclosure Requirements section Provisions must be made for adequate clearances for servicing and for operation as noted in this manual refer t...

Page 9: ...onsole Module 1 Remove the outer top top back guard bottom back guard and rear electrical box cover refer to the Component Identification drawing 2 Remove 8 bolts washers and lock washers L figure 1 t...

Page 10: ...o its mating plug This plug is similar to the one in the lower right corner that was disconnected earlier 9 Reinstall the retaining screws top and bottom 10 Reinstall the bottom hinge block This was t...

Page 11: ...e exhaust ductwork system Exhaust back pressure measured by a manometer magnehelic in the exhaust duct must be no less than 0 and must not exceed 0 7 in WC 1 7 mb Fresh Air Supply Requirements _______...

Page 12: ...e nearest obstruction refer to the diagram Exhaust Transition Piece This dryer is equipped with a 12 inch to 10 inch exhaust transition piece installed for use with 10 inch ducting If the exhaust duct...

Page 13: ...proper venting information Multiple Dryer Common Venting If it is not feasible to provide separate exhaust ducts for each dryer ducts from individual dryers may be channeled into a common main duct T...

Page 14: ...14 American Dryer Corp 113546 2 MULTIPLE DRYER VENTING HORIZONTAL AT COMMON DUCT MULTIPLE DRYER VENTING VERTICAL AT COMMON DUCT...

Page 15: ...wire size 4 24 14 Not available until September 2014 Grounding A ground earth connection must be provided and installed in accordance with local state and national regulations or codes of the country...

Page 16: ...be grounded A ground lug has been provided for this purpose Input connection wiring must be sized properly to handle the dryer s current draw This information is printed on the dryer s rating plate I...

Page 17: ...re the input wiring enters 3 Phase 3 Wiring Connections Hookup The electrical connections on all 3 phase 3 gas and steam dryers are made into the rear service box located at the upper left area of the...

Page 18: ...atings shown on the rating plate are for elevations up to 2 000 feet 610 meters unless elevation requirements of over 2 000 feet 610 meters were specified at the time the dryer order was placed with t...

Page 19: ...Input Gas Consumption Orifice Injector Data For CE European Models Only GAS SPECIFICATIONS FOR NON CE APPROVED DRYERS Gas Type Nominal Heating Value Supply Pressure Gross Heat Input Orifice Size Orif...

Page 20: ...ccessible for a pressure gauge connection must be installed in the main gas supply line immediately upstream of the dryers IMPORTANT Pipe joint compounds that resist the action of natural L P and buta...

Page 21: ...tructions included in kit envelope 92 1022 supplied 9 To convert the gas valve for use with regulated L P gas refer to the instructions included in kit envelope 92 0659 supplied 10 Reverse procedure f...

Page 22: ...ly a glass or transparent plastic tube with a scale graduated in inches or millibars When it is filled with water and pressure is applied the water in the tube rises showing the exact gas pressure Gas...

Page 23: ...ly in place Be sure the lint door drawer is securely in place Rotate the tumbler drum by hand to be sure it moves freely Check bolts nuts screws terminals and fittings for tightness and security Check...

Page 24: ...mation ___________ Service Service must be performed by a qualified trained technician If service is required contact the reseller from whom the equipment was purchased If the reseller cannot be conta...

Page 25: ...t be accepted IMPORTANT No replacements credits or refunds will be issued if the claim cannot be processed due to insufficient information The party filing the claim will be notified in writing either...

Page 26: ...exhaust and ventilation gases reducing dryer performance Cleaning of the dryer s internal exhaust may require removing the lint screen See the instructions above for removing the lint screen Check an...

Page 27: ...____ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______...

Page 28: ...IL SWITCH CLOSED FAULT Sail switch is closed should be open at the start of a cycle O O O SAIL SWITCH OPEN FAULT Sail switch remained open after the cycle started Should have closed BURNER HIGH LIMIT...

Page 29: ...closed before starting SAIL SWITCH OPEN Sail switch failed to close after starting BURNER HI LIMIT Oven thermostat switch has opened EXHAUST HI LIMIT Tumbler thermostat switch has opened BURNER CONTRO...

Page 30: ...ADC Part No 113546 2 08 13 14...