113546 - 2
www.adclaundry.com
19
Shaded areas are stated in metric equivalents
* Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Gas Specifications for AGA Approved Dryers (Australia)
Gas
Type
Supply
Pressure
Gross Heat Input
Orifice Size
Orifice
(Injector)
Quantity
Burner
Pressure
kPa
MJ/h
kW
DMS
mm
kPa
Natural
1.7-3.2
263.7
73.27
18
4.305
3
0.90
Propane
2.75
263.7
73.27
37
2.642
3
2.50
Heat Input / Gas Consumption / Orifice (Injector) Data (For Non-CE [European] Models Only)
Shaded areas are stated in metric equivalents
* Gas valve’s internal regulator disabled.
** Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
*** Nominal supply pressure.
Heat Input / Gas Consumption / Orifice (Injector) Data (For AGA [Australian] Models Only)
*
Shaded areas are stated in metric equivalents
*
Gas valve’s internal regulator disabled.
**
Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
Heat Input / Gas Consumption / Orifice (Injector) Data (For CE [European] Models Only)
GAS SPECIFICATIONS FOR NON-CE APPROVED DRYERS
**
Gas
Type
Nominal
Heating Value
Supply
Pressure
Gross
Heat Input
Orifice Size
Orifice
(Injector)
Quantity
Burner
Pressure
Btu/ft
3
in WC
Btu/hr
kW
DMS
mm
in WC
Natural
1,000
7.0-13.0
250,000
73.27
18
4.305
3
3.5
*
Liquid Propane
2,500
11
250,000
73.27
37
2.642
3
10.5
GAS SPECIFICATIONS FOR CE APPROVED DRYERS
**
Gas
Type
Nominal
Heating Value
Supply
Pressure
***
Gross
Heat Input
Fuel
Consumption
Orifice Size
Orifice
(Injector)
Quantity
Burner
Pressure
Btu/ft
3
mb
Btu/hr
kW
DMS
mm
mb
Natural (I
2H
/I
2E
)
1,000
15-30
250,000
73.27
6.802 M
3
/hr
18
4.305
3
9.0
Natural (I
2L
)
830
20-35
250,000
73.27
8.196 M
3
/hr
18
4.305
3
12.0
Natural (I
2ELL
)
830
15-30
250,000
73.27
8.196 M
3
/hr
18
4.305
3
12.0
*
Natural (I
2E+
)
1,000
20
250,000
73.27
6.802 M
3
/hr
27
3.658
3
—
830
25
250,000
73.27
8.196 M
3
/hr
27
3.658
3
—
*
Butane (I
3+
)
3,175
28-30
250,000
73.27
5.074 kg/hr
41
2.438
3
—
*
Propane (I
3+
)
2,500
37
250,000
73.27
5.074 kg/hr
41
2.438
3
—
Butane (I
3B/P
)
3,175
28-30/50
250,000
73.27
5.074 kg/hr
37
2.642
3
20.0
Propane (I
3P
)
2,500
28-30/50
250,000
73.27
5.074 kg/hr
37
2.642
3
25.0
Summary of Contents for AD120i
Page 30: ...ADC Part No 113546 2 08 13 14...