6 SEQUENTIAL DIAGNOSTICS (Optional)
In case the client has ordered the option:
One Sequential Diagnostics kit must be installed for each dimmer cabinet in the
installation.
The sequential diagnostics function is similar in function to the diagnostics already used in
the EURODIM 3. The dimmer channels are examined one after the other (sequential) and
the value is reported either to the local Human Interface or a remote program running the
TTD Management Software.
The communication to a single remote reporting pc is done via RDM protocol based on an
Ethernet Network to a Personal Computer with the Windows Operating System running
the TTD RDM Management Software. The Ethernet information is generated by each
EURODIM Twin Tech controller and physically available for each individual controller on
dedicated RJ45 connectors (Two possible per cabinet if double controller options are
used).
The TTD RDM Management Software and the necessary hardware are available as option
for the EURODIM Twin Tech cabinet, which shall be ordered separately installation.
Standard functions include
•
Presence of Mains and DMX signal
•
Processor (active) check
•
Over Temperature
•
Fan Failure (Information per FAN!)
•
DMX Control Levels
•
Local test of a dimmer (steady, flash or chaser)
•
Automatic self-test of control electronics.
Error messages and all events/parameters are available for display locally on the
EURODIM Twin Tech Human Interface Controller and/or remotely on the TTD RDM
Dimmer Manager PC connected via an Ethernet Network.
Scan Load and the related functions are pre-show
1
test routines providing additional
information on the status of each dimmer, i.e.
•
Value of the dimmer load (kW)
•
Deviation from reference load
•
No load, overload warnings
•
Short-Circuit
The necessary hardware to perform Sequential Diagnostic measurements is an option and
which shall be installed at the client’s site.
1
Sequential Diagnostics cannot be used during a show, since control is disabled and the dimmers system
runs through a test routine.
Summary of Contents for EURODIM Twin Tech
Page 1: ...M 3213 1106 01 213 Installation Manual V 1 2 EURODIM Twin Tech ...
Page 2: ......
Page 13: ...EURODIM TWIN TECH User Manual page 11 Issue 2 1 www adbstagelight com 3 DESCRIPTION ...
Page 50: ...EURODIM TWIN TECH User Manual page 48 Issue 2 1 www adbstagelight com 3 8 8 142 990 596 216 ...
Page 63: ...EURODIM TWIN TECH User Manual page 61 Issue 2 1 www adbstagelight com 14 CONFIGURATION TABLES ...
Page 65: ...EURODIM TWIN TECH User Manual page 63 Issue 2 1 www adbstagelight com ...
Page 67: ...EURODIM TWIN TECH User Manual page 65 Issue 2 1 www adbstagelight com Notes ...
Page 68: ......
Page 70: ......
Page 71: ...M 3213 E 09p Subject to modifications www adbstagelight com info adblighting com ...