Amplitude
amplitude unit
Value type
RMS, 0-P, P-P
Speed
speed unit
Mass
mass unit
Rotor Settings
Parameters of the rotor are defined here. All parameters are optional. It enables calculation of the balancing
quality factor according to ISO1940.
Rotor mass
rotor mass in kg
Correction Radius
radius to which the balancing mass will be mounted
Balance Quality Grade
the value, which is defined by rotor type according to ISO1940
If entered, the recommended trial can be computed.
Enter Trial
For trial runs only. Enter the value of the trial mass.
Enter Values
You can manually enter the values instead of measuring them (balancing calculator function).
Enter DF
For trial runs only; you can enter the dynamic factor of the rotor. The trial run measurement is not needed in this
case. The value of the dynamic factor is known from previous measurements on the same rotor. See below.
Report
The function creates a balancing report in .rtf format (MS Word) and saves it to the VA3_DISC (directory
va3/report) for PC downloading.
Vector
This shows the drawing of amplitude/phase vector development during the balancing process. The drawing is
also included in the balancing report.
Description: R1-RUN1, R3-RUN3, T1-T3 -trims 1-3.