Measurement
Press Start to initiate the measurement. The speed detection runs first (see chapter Speed Detection).
Status bar
There is a Status bar at the top part of the display. It provides information about the settings and status of the
measurement. If the measurement is running there is a red icon labeled meas flashing in the top right corner.
Ch1:
The number of the channel being used
1140 RPM Auto:
the value and unit of speed and the method of speed detection
Auto: the speed is detected from the frequency spectrum
Manual: the speed is entered manually by the user
Tacho: the speed is detected by the tacho
Alarms:
The standards used for stating the limit values
Measurement screens
You can switch between the measurement screens with the left and right arrow buttons.
Overall (RMS) and Peak (0-P) values
Measurement of Overall and Peak value in the following frequency bands:
velocity: 10 Hz - 1000 Hz
acceleration: 0.5 kHz – 25.6 kHz
The colour describing the condition of the machine (green, yellow, red) is determined according to the speed
value and vibration value (RMS, Peak).
Spectrum up to 200Hz – mechanical looseness detection
FFT analysis of vibrations in the range 2 Hz - 200 Hz in mm/s RMS
The 3 maximum peaks found are displayed
The peaks are arranged according to the vibration amplitude.