56
Clear Project Data
Deletes the measured data in the project.
Project screen
Select the required project and press OK. If the selected project contains measured data, the record preview is
shown. If there are no measured data, the record project settings appear.
Record Settings
Press Menu (F2) and select Record Settings.
Fs:
Record sampling frequency (max 65536 Hz).
The record frequency range is shown below.
AC1 – AC3:
Switches the required AC channels on/off.
DC1 – DC3:
Switches the required DC channels on/off.
Tacho:
Switch this on if you wish to record the Tacho channel.
Length:
You can set up the required record length. You can enter the required length in minutes or seconds. If you
select the option Manually stopped, the record will be stopped when you press the Stop button or when the
available memory is full.
The available space is displayed below – the available space in memory (MB) and possible record length
(hh:mm:ss).
If the entered length exceeds the 1000 MB limit, it will be shortened automatically. The message Required
length shortened! appears in this case.
Start of Rec:
freerun
The recording starts immediately after pressing Start (F3).
external
The recording starts when the signal appears in Tacho channel.
amplitude
The recording starts when the signal from the Tacho channel exceeds the amplitude
trigger level (see Ampl Trig Level below
Pretrig:
You can enter the length of the record before the Trigger (in minutes or seconds).