5-5
Duralink64 Drivers for NetWare
Installing the Duralink64 Driver during
NetWare 6.0/5.x OS Installation
The procedures for installing NetWare 6.0, 5.1, and 5.0 are the
same.
The Duralink64 driver is embedded only in the NetWare 5.1
installation CD.
Follow this procedure when installing the Duralink64 driver
during the installation of NetWare 6.0/5.x. Install NetWare
following the NetWare on-screen instructions until you reach the
Network Boards screen.
Note:
If you are using the ANA-62011LV, ANA-64022LV, or
ANA-64044LV NIC with NetWare 5.1, you must use the
driver that came with the NIC. Do not use the driver
embedded with NetWare 5.1.
1
Copy the NetWare driver files from the Duralink64 driver CD
to a floppy disk before installing the drivers onto the server. Do
not attempt to install Novell drivers from the CD during the OS
installation.
a
On a separate Windows PC, insert the Duralink64 driver CD
into the CD-ROM drive and a blank DOS-formatted floppy
disk into the floppy disk drive.
b
Open the CD in Windows Explorer and double-click the
nwserver
directory (in the root of the CD).
c
Select the entire contents of the nwserver directory, and
copy it to the floppy disk.
d
The floppy disk now contains the Duralink64 driver files
and can be used to install drivers onto your NetWare server.
2
From the Network Boards window select Modify, and press
Enter
.
3
Select the Network Boards field, and press Enter.
4
If you are installing NetWare 5.x and are using the
ANA-62011LV, ANA-64022LV, or ANA-64044LV NIC, you
must remove the
adptsf.lan
driver that was autodetected and
listed. Press Delete to remove the embedded driver.