When using the generator, make sure the total load is within rated output of a
generator. Otherwise, generator damage may occur.
6. APPLICATION RANGE:
NOTICE
•
Do not overload. The total load of all electrical appliances must not exceed the
supply range of the generator. Overloading will damage the generator.
•
When supplying precision equipment, electronic controllers, PCs, electronic
computers, microcomputer based equipment or battery chargers, keep the
generator at a sufficient distance away to prevent electricalinterference from the
engine. Also ensure that electrical noise from the engine does not interfere with
any other electrical devices located near the generator.
•
If the generator is to supply medical equipment, advice should first be obtained
from the manufacturer, a medical professional or hospital.
•
Some electrical appliances or general-purpose electric motors have high starting
currents, and cannot therefore be used, even if they lie within the supply ranges
given in the above table. Consult the equipment manufacturer for further advice.
The overload indicator light comes on when total wattage exceeds the application
range.
TIP:
•
“~”means below.
•
Application wattage indicates when each device is used by itself.
•
The simultaneous usage of AC and DC power is possible but total wattage should
not exceed the rated output.
AC
Power factor
3500i
1
~
3000W
~
2400W
~
1200W
Rated voltage 12V
Rated current 8A
0.8-0.95
0.4-0.75
Efficiency 0.85
Generator rated output
Power factor
Frequency
1.0
~
3000W
~
2400W
96W(12V/8A)
AC
3000VA
0.8
DC
- -
EX:
DC
AGi3500
Inverter
50/60/50 e 60
100/120/230
3.3
3.0
1.0
ISO8528 G2
≤5
12 - 8
DC
Non-fuse Protector
AC Control by inverter overload
protect program
170FD-3
Single cylinder, 4-Stroke,
forced air cooling, OHV
212
Unleaded Gasoline
10
0.6
BPR6ES/BP6ES(NGK)
F7RTC/F7TC
Recoil start / Electric start
Generator 578×440×510
set
45
65
MODEL
Generator
Type
Rated frequency/Hz *
Rated voltage/V *
Max. output power/kW
Power factor
AC output quality
THD/%
Noise Level dB/LpA/LwA/K 4m
(3/4 load)
DC Output/ V-A
Overload protect
Engine
Engine
Engine type
Displacement/cc
Fuel type
Fuel capacity/L
Continue Running
Time (at rated power) / h
Net weight/kg
5.5
Oil Capacity/L
Spark Model No.
Starting mode
Length×Width×Height/mm
7. MAINTENANCE:
Maintenance:
Safety is an obligation of the owner. Periodic inspection, adjustment and lubrication
will keep your generator in the safest and most efficient condition possible.
The most important points of generator inspection and lubrication are explained on
the following pages.
If you are not familiar with maintenance work, have a franchised dealer do it for
safety.
WARNING:
Maintenance chart:
•
Stop the engine before starting maintenance work.
• Use only
franchised
dealer specified genuine parts for replacement. Ask an
authorized f
ranchised
dealer for further attention.
WARNING:
Item
Routine
Pre-operation
check (daily)
6 months
or 100 hrs
12 months
or 300 hrs
Spark plug
Fuel
Fuel hose
Oil
Air filter
Muffler
screen
Spark arrester
Check condition.
Clean and replace
if necessary.
Check fuel level
and leakage.
Check fuel hose for
cracks or damage.
Replace if
necessary.
Check oil level
in engine.
Replace.
Check condition.
Clean.
Check condition.
Clean and replace
if necessary.
Check condition.
Clean and replace
if necessary.
(1)
(2)