53
“ON” Direct current is output.
“OFF”
Direct current is not output.
The DC protector turns to “OFF”
automatically when electric device being
connected to the generator is operating
and current above the rated flows. To use
this equipment again, turn on DC
protector by pressing its button to “ON” .
Reduce the load of the
connected electric device
below the specified rated
output of the generator if
the DC protector turns off.
If the DC protector turns off
again, stop using the
device immediately and
consult a fran
chised dealer.
3. CONTROL FUNCTION:
DC protector.
NOTICE
This is the terminal
for connecting special
cables for parallel running of two generator.
The parallel running requires two generator
and the special cables. (The rated output in
parallel running is 5.6Kva and the rated current
is 60A/100V;50A/120V;26A/230V.)
The handing, operation procedure and the
notes on usage are described in the PARALLEL
RUNNING KIT OWNER'S MANUAL included in
the Parallel.
Ground (Earth) terminal connects the earth
line for prevention of electric shock. When the
electric device is earthed, always the generator
must be earthed.
During the operation and idle period of
machine, brake timely and switch to “STOP”.
In case of the machine required to be move,
switch the brake to “RUN”.
Ground (Earth) terminal.
Parallel operation outlets.
Brake.
3. CONTROL FUNCTION: