3. CONTROL FUNCTION:
When the oil level falls below the lower level,
the oil warning light comes on and then the
engine stops automatically. Unless you refill
with oil, the engine will not start again.
Tip:
If the engine stalls or does not start, turn
the engine switch to “ON” and then pull
the recoil starter. If the oil warning light
flickers for a few seconds, the engine oil is
insufficient. Add oil and restart.
During the normal operation, the
operation key
③
for switching the display and
recycling showing: voltage- current-power-
accumulative time-current time.
Liquid crystal display
Normal operation:
In case of failed operation:
U> a: AC over voltage, indicating the character
of AC (alternative indication of AC
and digit).
b: DC over voltage, indicating the character
of DC (alternative indication of DC
and digit).
U< a: AC under-voltage, indicating the
character of AC (alternative indication
of AC and digit).
b: DC under-voltage, indicating the
character of DC (alternative indication
of DC and digit).
I> Output over current of generator.
Output short circuit of generator.
Over heat of generator.
Maintenance time.
Digital display meter.
Oil warning light.
Multimeter
Liquid crystal display
Operating key
Oil warning light
Overload indicator light
AC pilot light
The AC pilot light comes on when the engine
starts and produces power.
The overload indicator light comes on when
an overload of a connected electrical device
is detected, the inverter control unit overheats,
or the AC output voltage rises. Then, the AC
protector will trip, stopping power generation
in order to protect the generator and any
connected electric devices. The AC pilot light
(Green) will go off and the overload indicator
light (Red) will stay on, but the engine will not
stop running.
When the overload indicator light
comes on and power generation
stops, proceed as follows:
1. Turn off any connected electric
devices and stop the engine.
2. Reduce the total wattage of
connected electric devices within the
rated output.
3. Check for blockages in the cooling
air Inlet and around the control unit. If
any blockages are found remove.
4. After checking, restart the engine.
The overload indicator light may come on
for a few seconds at first when using
electric devices that require a large
starting current, such as a compressor or
a submergible pump. However, this is not
a malfunction.
3. CONTROL FUNCTION:
Overload indicator light (RED).
AC pilot light (GREEN).
TIP: