57
TIP:
• The generator can be used with the rated output load at standard atmospheric
conditions.
• “Standard atmospheric conditions ”; Ambient temperature 25°C.
• Barometric pressure 100kPa; Relative humidity 30%
• The output of the generator varies due to change temperature, altitude (lower
air pressure at higher altitude) and humidity.
• The output of the generator is reduced when the temperature, the humidity and
the altitude are higher than standard atmospheric conditions.
• Additionally, the load must be reduced when using in confined areas, as
generator cooling is affected.
5. OPERATION:
NOTICE
Never operate the engine in a closed area or it may cause unconsciousness and
death within a short time. Operate the engine in a well ventilated area. The
generator has been shipped without engine oil. Do not start the engine
till fill with the sufficient engine oil.
Starting the engine.
Before starting the engine, do not
connect any electric devices.
Turn the ESC switch to “OFF”.
Turn the 3 in 1 switch to “CHOKE”.
a. Ignition circuit is switched on.
b. Fuel is switched on.
c. Choke is switched off.
TIP:
The choke is not required to
start a warm engine.Push
the choke knob in to the
position “ON”.
5. OPERATION:
After the engine starts, warm it up
until it does not stop when the choke
knob is returned to the “ON” position.
TIP:
When starting the engine,
with the ESC “ON” and there is
no load on the generator:
In ambient temperature below
0
°
C
(32
°F)
,
the engine will run at
the rated (3600r/min) for 5
minutes to warm up the engine.
In ambient temperature below
5°C (4
1°F)
,
t
he engine will run at
the rated rpm (3600 rpm) for 3
minutes to warm up the engine.
The ESC unit operates normally
after the above time period,
while the ESC is “ON”.
Electric start.
Turn the engine switch on the control
panel to ON. Press it to START
or turn key right if it's electrical start
state, then generator unit can be
started. In order to extend the
service life of the storage battery,
do not press on the switch for more
than 3 seconds and the interval
between two pressings should be
longer than 10 seconds.
Recoil start.
Grasp the carrying handle firmly
to prevent the generator from
falling over when pulling the
recoil starter.