![ACTAtek ACTAtek3 ACTA3-1k-FAM-SM-C Manual Download Page 74](http://html1.mh-extra.com/html/actatek/actatek3-acta3-1k-fam-sm-c/actatek3-acta3-1k-fam-sm-c_manual_2842275074.webp)
ACTA
tek
Pte Limited
ACTAtek3 Manual
74
8.4.5.
Terminal Clock
The “Terminal Clock” can be modified according to the region you are in. It is extremely
useful to have a correct timing for all time attendance purposes or for reporting purposes
since that’s the time the system will record for any access.
If the SNTP (Time server) is enabled, then the ACTAtek3
TM
will follow the time of the local
time server, either provided by the government or other authorities in the region.
If the SNTP is disabled, the ACTAtek3
TM
will either have to follow the time on the PC or a
time can be set for the device according to the local time settings.
To let ACTAtek3
TM
to follow the time on the PC, select “On” for Auto Adjust. To disable this
auto adjust, select “Off” and the time setting will be available for users to input the “New
Date” and “New Time”.
Also, time can be set according to regional Time Zones as presented here.
Click “Set” to save any modifications made.