ACS-CONTROL-SYSTEM GmbH
l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l [email protected]
42
Environmental conditions
The permitted environmental temperature range results from the combination of standard range and
expansion, whereby the range is defined by the narrowest limitation.
Environmental temperature
-20°C...+50°C
Expansion
Backlight LCD ≤ 80% >> -20°C...+60°C
Backlight LCD ≤ 60%
>>
-20°C...+70°C
Protection
IP68 [≤ 1 mWs-1h] (EN/IEC 60529)
Climatic classification
4K4H [-20…+55°C / 4…100%] (EN/IEC 60721-3-4)
Shock classification
15 g [11ms] (EN/IEC 60068-2-27)
Vibration classification
4 g [10 - 500 Hz] (EN/IEC 60068-2-6)
EM compatibility
Operation device class B / Industrial range (EN/IEC 61326)
Weight
0,7 kg
Materials - process wetted
Sensor
PVDF
Process connection
Steel 1.4404 (316L) / 1.4571 (316Ti)
Gaskets
EPDM – ethylene-propylene-dienmonomere
Materials - not process wetted
Terminal enclosure
CrNi-steel
Control panel surface
PC / PES
Electrical connection part
Device plug PUR
Pressure compensation element Enclosure PBT
Membrane PES
Gaskets
FPM – fluorelastomere (Viton®)
Data memory
Memory size
1 million measuring values
Memory system
Ring memory
Memory rate
1…99999 s