ACS-CONTROL-SYSTEM GmbH
l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l [email protected]
23
Enclosure rating
IP 67
Weight
340 g
350 g
420 g
460 g
Electronics
Supply voltage
1)
18 V DC ... 30 V DC
Ripple
2)
< 5 V
PP
Power consumption
3)
< 180 mA
Initialization time
< 5 s
Ansprechzeit
4)
Filter off 100 ms, filter low 300 ms,
filter medium 1 s, filter strong 4.2 s
Protection class
III
Electrical connection
M12x1, 5-pin
M12x1, 8-pin
(depending on type)
Electronics
1)
1 analog output: 4 mA ... 20 mA, 0 mA ... 20
mA current flow and temperature, 1 pulse/
status output: PNP-transistor output for
flow rate meter, empty pipe detection, flow
monitoring, dosing output, flow
direction
1 analog output: 4 mA ... 20 mA, 0 mA ... 20
mA current flow and temperature, 2 pulse/
status output: PNP-transistor output for
flow rate meter, empty pipe detection, flow
monitoring, dosing output, flow direction,
1 digital input for dosing and counter reset
(depending on type)
Output load
< 500 Ohm
Lower signal level
3.8 mA ... 4 mA
Upper signal level
20 mA ... 20.5 mA
Impuls/frequency output
0 kHz ... 10 kHz
Puls width
< 1 s
Signal voltage HIGH
U
V
- 2 V
Signal voltage LOW
< 2 V
Output current
5)
< 100 mA
Inductive load
1 H
Capacitive load
100 nF
1) All connections are reverse polarity. All outputs are overload and short-circuit protected.
2) May not exceed or fall short of VS tolerances.
3) Without load.
4) Analog output and display.
5) There are 100 mA for each output pnp and npn available.
Ambient data
Ambient temperature, operation
0 °C ... +60 °C
Ambient temperature, storage
-20 °C ... +70 °C
Summary of Contents for Flowcont UN