ACS-CONTROL-SYSTEM GmbH
l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l [email protected]
22
Technical data
Features
NW10
NW15
NW20
NW25
Measuring
principle
Ultrasonic sensor
Medium
Fluids
Nominal width
measuring tube
NW10
NW15
NW20
NW25
Process
temperature
0 °C ... +80 °C
Process pressure
Max. 16 bar
Max. 10 bar
EHEDG approval
yes
Performance
NW10
NW15
NW20
NW25
Minimum flow
1)
0.3 l/min
0.9 l/min
3.5 l/min
5 l/min
Maximum flow
21 l/min
36 l/min
60 l/min
240 l/min
Inlet zone
10 cm
30 cm
50 cm
80 cm
Outlet zone
0 cm
5 cm
10 cm
20 cm
Conductivity
No limitation
Accuracy
2)
2% (of final value) /optional 1% of r/- 3 mm/s
Reproduzierbarkeit
0,5 %
Auflösung
0,003 l/min
0,006 l/min
0,012 l/min
0,03 l/min
1) At constant flow rate.
2) reference condition:Medium: water, gas-free, fully-filled measuring tube, no cavitation, Medium temperature 20 ° C, Ambient temperature 20 ° C ...
25 ° C, Compliance with the inlet zone and outlet zone, Warm-up time electronic: 30 min
Mechanics
NW10
DN15
DN20
DN25
Process
connection
G 1/2
1/2“ NPT
Clamp 11864
G 3/4
3/4“ NPT
Clamp 11864
G 1
1“ NPT
Clamp 11864
G 1 1/4
1 1/4“ NPT
Clamp 11864
Wetted parts
PSU
Housing
material
PSU
Summary of Contents for Flowcont UN