background image

SERIES IP440 INDUSTRIAL I/O PACK                                32-CHANNEL ISOLATED DIGITAL INPUT MODULE
___________________________________________________________________________________________

- 16 -

CABLE: MODEL 5029-900

Type: Model 5029-900 APC8600 High-Density Cable:  A 36-inch

long interface cable that mates the high-density (25mil pitch)
50-pin I/O connectors of the APC8600 PC/AT ISAbus carrier
board, to the high density connectors on the APC8600
Termination Panels (described below).

Application: Used with the APC8600 PC carrier and  termination

panel.  It mates the high-density (25mil pitch) 50-pin I/O
connectors of the APC8600 PC/AT ISAbus carrier board, to
the high density connectors on the APC8600 Termination
Panel (described below).

Length: 36-inches
Cable:  50-wire flat ribbon cable, 28 gage, Non-Shielded,

T&B/Ansley Part 135-050 or equivalent.

Headers:  50-pin, high-density, 25-mil pitch, female header.

Header- T&B Ansley Part 311-050302 or equivalent.

Keying:  Headers at both ends have polarizing key to prevent

improper installation.

Shipping Weight:  1.0 pound (0.5Kg) packaged.

TERMINATION PANEL:  MODEL 5025-552

Type:  Termination Panel For AVME9630/9660 Boards

Application:  To connect field I/O signals to the Industrial I/O
Pack (IP).  

Termination Panel:  

Acromag Part 4001-040

(Phoenix Contact Type FLKM 50).  The 5025-552 termination
panel facilitates the connection of up to 50 field I/O signals
and connects to the AVME9630/9660 3U/6U non-intelligent
carrier boards (A-D connectors only) via a flat ribbon cable
(Model 5025-550-x or 5025-551-x).  The A-D connectors on
the carrier board connect the field I/O signals to the P2
connector on each of the Industrial I/O Pack modules.  Field
signals are accessed via screw terminal strips.  The terminal
strip markings on the termination panel (1-50) correspond to
P2 (pins 1-50) on the Industrial I/O Pack (IP).  Each Industrial
I/O Pack (IP) has its own unique P2 pin assignments.  Refer
to the IP module manual for correct wiring connections to the
termination panel.

Schematic and Physical Attributes:  See Drawing 4501-464.
Field Wiring:  50-position terminal blocks with screw clamps.

Wire range 12 to 26 AWG.

Connections to AVME9630/9660:  P1, 50-pin male header with

strain relief ejectors.  Use Acromag 5025-550-x or 5025-551-
x cable to connect panel to VME board.   Keep cable as short
as possible to reduce noise and power loss.

Mounting:  Termination panel is snapped on the DIN mounting

rail.

Printed Circuit Board:  Military grade FR-4 epoxy glass circuit

board, 0.063 inches thick.

Operating Temperature:  -40

°

C to +100

°

C.

Storage Temperature:  -40

°

C to +100

°

C.

Shipping Weight

:  1.25 pounds (0.6kg) packaged.

TERMINATION PANEL:  MODEL 5029-910

Type:  Screw-Terminal Termination Panel For Acromag APC8600

PC/AT ISAbus Carrier Boards.

Application: This panel converts the high-density ribbon-cable

connectors coming from the APC8600 carrier board
(Acromag cable Model 5029-900) to screw terminals, for
direct-wired interfaces.  This panel facilitates the connection
of up to 50 field I/O signals and connects to the APC8600
PC/AT ISAbus carrier board via high-density (25-mil pitch) flat
ribbon cable and connectors (see cable Model 5029-900).
The A & B connectors on the carrier board connect the field
I/O signals to the P2 connector on each of the Industrial I/O
Pack modules.  Field signals are accessed via screw terminal
strips.  Each Industrial I/O Pack (IP) has its own unique P2
pin assignments.  Refer to the IP module manual for correct
wiring connections to the termination panel.

Field Wiring:  50-position terminal blocks with screw clamps.

Wire range 12 to 26 AWG.

Connections to APC8600:  P1, 50-pin, high-density male header

with strain relief.

Mounting:  Termination Panel includes mounting holes.
Printed Circuit Board:  Military grade FR-4 epoxy glass circuit

board, 0.063 inches thick.

Operating Temperature:  -40

°

C. to +85

°

C.

Storage Temperature:  -55

°

C to +125

°

C.

Shipping Weight

:  1.25 pounds (0.6kg) packaged.

TRANSITION MODULE: MODEL TRANS-GP

Type:  Transition module for AVME9630/9660 boards.
Application:  To repeat field I/O signals of IP modules A through

D for rear exit from VME card cages.  This module is
available for use in card cages which provide rear exit for I/O
connections via transition modules (transition modules can
only be used in card cages specifically designed for them).  It
is a double-height (6U), single-slot module with front panel
hardware adhering to the VMEbus mechanical dimensions,
except for shorter printed circuit board depth.  Connects to
Acromag termination panel 5025-552 from the rear of the
card cage, and to AVME9630/9660 boards within card cage,
via flat 50-pin ribbon cable (cable Model 5025-550-X or 5025-
551-X).

Schematic and Physical Attributes:  See Drawing 4501-465.
Field Wiring:  100-pin header (male) connectors (3M 3433-D303

or equivalent) employing long ejector latches and 30 micron
gold in the mating area (per MIL-G-45204, Type II, Grade C).
Connects to Acromag termination panel 5025-552 from the
rear of the card cage via flat 50-pin ribbon cable (cable Model
5025-550-X or 5025-551-X).

Connections to AVME9630/9660: 50-pin header (male)

connectors (3M 3433-1302 or equivalent) employing long
ejector latches and 30 micron gold in the mating area (per
MIL-G-45204, Type II, Grade C).  Connects to
AVME9630/9660 boards within the card cage via flat 50-pin
ribbon cable (cable Model 5025-550-X or 5025-551-X).

Mounting:  Transition module is inserted into a 6U-size, single-

width slot at the rear of the VMEbus card cage.

Printed Circuit Board:  Six-layer, military-grade FR-4 epoxy glass

circuit board, 0.063 inches thick.

Operating Temperature:  -40

°

C to +85

°

C.

Storage Temperature:  -55

°

C to +105

°

C.

Shipping Weight:  1.25 pounds (0.6Kg) packaged.

Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

Summary of Contents for IP440 Series

Page 1: ...ess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demo...

Page 2: ...RATED 30765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 1996 Acromag Inc Printed in the USA Data and specifications are subject to change without...

Page 3: ...his is especially important where economic property loss or human life is involved It is important that the user employ satisfactory overall system design It is agreed between the Buyer and Acromag th...

Page 4: ...your carrier board to ensure compatibility with the following interface products Cables Model 5025 551 X Shielded Cable or Model 5025 550 X Non Shielded Cable A Flat 50 pin cable with female connector...

Page 5: ...in the mating area Threaded metric M2 screws and spacers are supplied with the module to provide additional stability for harsh environments see Mechanical Assembly Drawing 4501 434 The field and logi...

Page 6: ...d to avoid incorrect assembly 3 0 PROGRAMMING INFORMATION ADDRESS MAPS This board is addressable in the Industrial Pack I O space to control the configuration and status monitoring of 32 digital input...

Page 7: ...IN24 IN31 07 08 Not Driven4 READ WRITE2 Port 4 NOT USED 09 0A Not Driven4 READ WRITE2 Port 5 NOT USED 0B 0C Not Driven4 READ WRITE2 Port 6 NOT USED 0D 0E Not Driven4 READ WRITE Port 7 WRITE MASK REGI...

Page 8: ...0 ODD Base Addr INDEPENDENT FIXED FUNCTION REGISTERS 10 1C NOT USED2 11 1D 1E Not Driven1 READ WRITE Interrupt Enable Register Bit 0 1 enables INTREQ0 Software Reset Generator Bit 1 1 Generates Reset...

Page 9: ...of this model Writing a 1 to bits 0 3 of the Mask Register will mask ports 0 3 respectively from inadvertent writes A read of this register will return the status of the mask in bits 0 3 Enhanced Mode...

Page 10: ...IN31 Bank Select Register Enhanced Mode Bank 1 Port 7 Write Only Bits 6 7 of this register are used to select monitor the bank of registers to be addressed In Enhanced Mode three banks banks 0 2 of e...

Page 11: ...t Cycles INTSEL to occur This bit is cleared following a system reset but not a software reset see below Writing a 1 to the bit 1 position of this register will cause a software reset to occur be sure...

Page 12: ...440 2 models and 38 60V IP440 3 models Inputs are non inverting and inputs left floating not recommended will register a low false 0 input indication In both the Standard and Enhanced operating modes...

Page 13: ...ting the interrupt have been cleared or return to normal and the event sense flip flop has been cleared by writing 0 to the corresponding bit position of the Event Sense Status Register or until the I...

Page 14: ...ity of data contention between the built in output circuitry and the devices driving these inputs Write 01H to the port 7 address to mask writes to port 0 11 Read 01H from the port 7 address to verify...

Page 15: ...cedures in Section 2 Preparation For Use have been followed Also refer to the documentation of your carrier board to verify that it is correctly configured Replacement of the module with one that is k...

Page 16: ...aximum Diode I R Series input current limiting resistors are 2 2K IP440 1 12K IP440 2 or 27K IP440 3 and installed on board Input Current Varies per model number and input signal voltage level For Mod...

Page 17: ...ensity ribbon cable connectors coming from the APC8600 carrier board Acromag cable Model 5029 900 to screw terminals for direct wired interfaces This panel facilitates the connection of up to 50 field...

Page 18: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...

Page 19: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...

Page 20: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...

Page 21: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...

Page 22: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: