background image

SERIES IP440 INDUSTRIAL I/O PACK                                32-CHANNEL ISOLATED DIGITAL INPUT MODULE
___________________________________________________________________________________________

- 4 -

For repairs to a product damaged in shipment, refer to the

Acromag Service Policy to obtain return instructions.  It is
suggested that salvageable shipping cartons and packing
material be saved for future use in the event the product must be
shipped.

This board is physically protected with
packing material and electrically
protected with an anti-static bag during
shipment.  However, it is
recommended that the board be
visually inspected for evidence of
mishandling prior to applying power.

The board utilizes static-sensitive
components and should only be
handled at a static-safe workstation.

CARD CAGE CONSIDERATIONS

Refer to the specifications for loading and power

requirements.   Be sure that the system power supplies are able
to accommodate the power requirements of the carrier board,
plus the installed IP modules, within the voltage tolerances
specified.

IMPORTANT:

 Adequate air circulation must be provided to

prevent a temperature rise above the maximum operating
temperature.

The dense packing of the IP modules to the carrier board

restricts air flow within the card cage and is cause for concern.
Adequate air circulation must be provided to prevent a
temperature rise above the maximum operating temperature and
to prolong the life of the electronics.  If the installation is in an
industrial environment and the board is exposed to environmental
air, careful consideration should be given to air-filtering.

BOARD CONFIGURATION

Power should be removed from the board when installing IP

modules, cables, termination panels, and field wiring.  Refer to
Mechanical Assembly Drawing 4501-434 and your IP module
documentation for configuration and assembly instructions.
Model IP440 digital input boards have no hardware jumpers or
switches to configure.

CONNECTORS

IP Field I/O Connector (P2)

P2 provides the field I/O interface connections for mating IP

modules to the carrier board.  P2 is a 50-pin female receptacle
header (AMP 173279-3 or equivalent) which mates to the male
connector of the carrier board (AMP 173280-3 or equivalent).
This provides excellent connection integrity and utilizes gold-
plating in the mating area.  Threaded metric M2 screws and
spacers are supplied with the module to provide additional
stability for harsh environments (see Mechanical Assembly
Drawing 4501-434).  The field and logic side connectors are
keyed to avoid incorrect assembly.

P2 pin assignments are unique to each IP model (see Table 2.1)
and normally correspond to the pin numbers of the field I/O
interface connector on the carrier board (you should verify this for
your carrier board).

Table 2.1:  IP440 Field I/O Pin Connections (P2)

Pin Description

Number

Pin Description

Number

IN00

1

IN16

21

IN01

2

IN17

22

P

IN02

3

P

IN18

23

O

IN03

4

O

IN19

24

R

NC

5

R

NC

25

T

IN04

6

T

IN20

26

IN05

7

IN21

27

0

IN06

8

2

IN22

28

IN07

9

IN23

29

ACOM

10

CCOM

30

IN08

11

IN24

31

IN09

12

IN25

32

P

IN10

13

P

IN26

33

O

IN11

14

O

IN27

34

R

NC

15

R

NC

35

T

IN12

16

T

IN28

36

IN13

17

IN29

37

1

IN14

18

3

IN30

38

IN15

19

IN31

39

BCOM

20

DCOM

40

No Connection

41

No Connection

42

No Connection

43

No Connection

44

No Connection

45

No Connection

46

No Connection

47

No Connection

48

No Connection

49

No Connection

50

Input channels of this module are divided into four ports of

eight channels each.  Channels of a port share a common signal
connection with each other.  Isolation is provided between ports
and between each port and the IP logic.  With respect to interrupt
generation and events, event polarities may be defined as
positive (low-to-high), or negative (high-to-low) for individual
nibbles (groups of 4 input lines, or half ports).  Change-of-State
detection would require 2 input channels--one detecting positive
events, one detecting negative events.

P2 pinouts are arranged to be compatible with similar

industry models.  This model is directly loopback compatible with
the Acromag Model IP445 Digital Output Module.  Likewise, pin
assignments are identical to those of Acromag Model IP400 40-
Channel Digital Input Boards for channels 0-31.  This model may
also interface with industry accepted I/O panels, termination
panels, and relay racks when used with the Acromag Model
5025-655 I/O Adapter Card.  Consult the factory for information
on these and other compatible products.

Refer to Drawing 4501-593 for example input connections.

See Drawing 4501-603 for loopback connections to Acromag
Model IP445 Output Modules.  Drawing 4501-603 also gives an
example of how to interface the IP440-1 with open-drain TTL
outputs signals.

Artisan Scientific - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisan-scientific.com

Summary of Contents for IP440 Series

Page 1: ...ess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demo...

Page 2: ...RATED 30765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 1996 Acromag Inc Printed in the USA Data and specifications are subject to change without...

Page 3: ...his is especially important where economic property loss or human life is involved It is important that the user employ satisfactory overall system design It is agreed between the Buyer and Acromag th...

Page 4: ...your carrier board to ensure compatibility with the following interface products Cables Model 5025 551 X Shielded Cable or Model 5025 550 X Non Shielded Cable A Flat 50 pin cable with female connector...

Page 5: ...in the mating area Threaded metric M2 screws and spacers are supplied with the module to provide additional stability for harsh environments see Mechanical Assembly Drawing 4501 434 The field and logi...

Page 6: ...d to avoid incorrect assembly 3 0 PROGRAMMING INFORMATION ADDRESS MAPS This board is addressable in the Industrial Pack I O space to control the configuration and status monitoring of 32 digital input...

Page 7: ...IN24 IN31 07 08 Not Driven4 READ WRITE2 Port 4 NOT USED 09 0A Not Driven4 READ WRITE2 Port 5 NOT USED 0B 0C Not Driven4 READ WRITE2 Port 6 NOT USED 0D 0E Not Driven4 READ WRITE Port 7 WRITE MASK REGI...

Page 8: ...0 ODD Base Addr INDEPENDENT FIXED FUNCTION REGISTERS 10 1C NOT USED2 11 1D 1E Not Driven1 READ WRITE Interrupt Enable Register Bit 0 1 enables INTREQ0 Software Reset Generator Bit 1 1 Generates Reset...

Page 9: ...of this model Writing a 1 to bits 0 3 of the Mask Register will mask ports 0 3 respectively from inadvertent writes A read of this register will return the status of the mask in bits 0 3 Enhanced Mode...

Page 10: ...IN31 Bank Select Register Enhanced Mode Bank 1 Port 7 Write Only Bits 6 7 of this register are used to select monitor the bank of registers to be addressed In Enhanced Mode three banks banks 0 2 of e...

Page 11: ...t Cycles INTSEL to occur This bit is cleared following a system reset but not a software reset see below Writing a 1 to the bit 1 position of this register will cause a software reset to occur be sure...

Page 12: ...440 2 models and 38 60V IP440 3 models Inputs are non inverting and inputs left floating not recommended will register a low false 0 input indication In both the Standard and Enhanced operating modes...

Page 13: ...ting the interrupt have been cleared or return to normal and the event sense flip flop has been cleared by writing 0 to the corresponding bit position of the Event Sense Status Register or until the I...

Page 14: ...ity of data contention between the built in output circuitry and the devices driving these inputs Write 01H to the port 7 address to mask writes to port 0 11 Read 01H from the port 7 address to verify...

Page 15: ...cedures in Section 2 Preparation For Use have been followed Also refer to the documentation of your carrier board to verify that it is correctly configured Replacement of the module with one that is k...

Page 16: ...aximum Diode I R Series input current limiting resistors are 2 2K IP440 1 12K IP440 2 or 27K IP440 3 and installed on board Input Current Varies per model number and input signal voltage level For Mod...

Page 17: ...ensity ribbon cable connectors coming from the APC8600 carrier board Acromag cable Model 5029 900 to screw terminals for direct wired interfaces This panel facilitates the connection of up to 50 field...

Page 18: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...

Page 19: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...

Page 20: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...

Page 21: ...Artisan Scientific Quality Instrumentation Guaranteed 888 88 SOURCE www artisan scientific com...

Page 22: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: