7
WARNING
:
Winterization
The system will be damaged if frozen. The system must be winterized and drained
according to the Winterization Procedure described in this manual. The system must be
winterized prior to temperatures falling below 32°F(0°C). Failure to do so may cause the
system to freeze, become damaged, and will void all warranties. Operating a damaged
system may lead to property or personal injury, and/or physical damage.
At the start of the next season, always prime the system before use.
WARNING:
Operational
All system parts and components must be installed in accordance with this manual and
local building and plumbing codes. The System has been designed and tested to offer
reliable service, provided it is installed, commissioned, operated, maintained and tested
in strict accordance to the safety instructions enclosed in this manual. Failure to
properly maintain the system will compromise performance and/or result in a failure to
control water quality which may lead to delivery of contaminated water. Consuming
contaminated water could result in serious injury or possibly death. Always prime the
system before use and before letting water into the piping system. Ensure that a post-
Activated Carbon filter is in place during operation of the system. Premature fouling of
the system is not covered by the warranty.
Always wash hands thoroughly with soap and water after performing any servicing
procedures on the System. ONLY OEM parts supplied by the manufacturer are to be
used when installing or servicing the ozone system. Failure to follow this instruction may
result in System damage, serious personal injury, death and/or property damage. Use
of non-
OEM parts will void the manufacturer’s warranty.
Certifications:
All Aclarus AOWT-7 Ozone Water Treatment Systems are certified by the National
Sanitation Foundation (NSF) protocol NSF-61: NSF/ANSI Standard 61 -
Drinking Water
System Components
was published in 1988 to establish minimum requirements for the
control of potential adverse human health effects from products that contact drinking
water.
NSF/ANSI Standard 61 includes criteria for testing and evaluating products to ensure
they do not leach contaminants into the water that would be a health concern. These
contaminants include those regulated by the United States Environmental Protection
Agency (USEPA) and Health Canada, as well as any other non-regulated compounds
that may be of concern. Systems are always certified by the Electrical Safety Authority
or equivalent prior to sale.
Point-of-Entry System tested and certified by NSF International under NSF/ANSI
Standard 61 for Materials Safety Requirements Only. Not Certified for
Contaminant Reductions or Structural Integrity by NSF International.
Summary of Contents for AOWT-7
Page 9: ...9 System Components...
Page 10: ...10 NOTE System components and tank may not be exactly as shown...
Page 47: ...47 Appendix Component Specification Sheets Pumps Specifications...
Page 48: ...48...
Page 49: ...49...
Page 50: ...50 Flow Switch Specifications...
Page 51: ...51...
Page 52: ...52 Mazzei Specifications...
Page 53: ...53 Gas Off 1 Specifications...