41
Repairing a plugged or leaking Mazzei (no suction when system is on):
1. Shut power to the ACLARUS System OFF.
2. Open bypass valves around the ACLARUS System or shut main water supply OFF.
3. Relieve water pressure on ACLARUS System by draining the ozone system.
4. Carefully remove the braided hose attached to the Mazzei.
5. Remove Mazzei from Aclarus system.
6. Examine the water inlet and outlet of the Mazzei for debris plugging the ports.
remove any debris and rinse Mazzei.
7. Carefully remove the suction port of the Mazzei. Note the small grey seal holding a
spring and ball in the Mazzei under the suction port.
8. Remove the grey seal slowly, making sure to not loosen the spring or ball located
behind the grey seal.
9. Remove the ball and spring and look for any debris in the Mazzei inlet port.
10. Look for any wear damage on the grey seal or the ball. Clear any debris and repair
Mazzei components as required.
11. Place spring and ball back into Mazzei and replace grey seal. Ensure ball is seated
in seal properly.
12. Replace Inlet cover and replace Mazzei into Aclarus system.
NOTE
: Ensure Mazzei flow indicator points in the right direction.
13. Replace braided hose.
14. Open main water supply. Open bypass assembly to pressurize system.
15. Inspect for leaks. If there are no leaks, turn Aclarus system on and run water to
initiate system. If leaks are present, repeat steps or order replacement parts for the
Mazzei.
Servicing and Replacing the Ozone Mixing Pump
4
The mixing pump mixes and recalculates water for introduction and saturation of ozone
in water. The pump generally fails for two reasons:
Running for extended period of time without required water supply.
Supply pressure is below normal or insufficient water supply.
Pump failure leads to these problems:
No water treatment because of improper mixing and saturation of ozone in
the water column.
Leaking seals caused by wear from sand or particulate in the water.
Motor breakdown from faulty part or operating pump with insufficient water
supply.
4
Refer to separate manual for your specific model.
Summary of Contents for AOWT-7
Page 9: ...9 System Components...
Page 10: ...10 NOTE System components and tank may not be exactly as shown...
Page 47: ...47 Appendix Component Specification Sheets Pumps Specifications...
Page 48: ...48...
Page 49: ...49...
Page 50: ...50 Flow Switch Specifications...
Page 51: ...51...
Page 52: ...52 Mazzei Specifications...
Page 53: ...53 Gas Off 1 Specifications...