Troubleshooting
Troubleshooting Reference Chart
Problem
Possible Cause
Solution
System does not
start with water
demand
.
Tripped or broken main
breaker.
Check the main power breaker and reset
or replace as appropriate
Tripped or broken 15 Amp
breaker.
Check the main power light . If the light is
off, but power switch is in the ON
position, cut power to Aclarus System
and check the 15 amp breaker located
on the Aclarus control panel. Reset or
replace as needed.
The source pump or flow
switch is not activating.
See Maintenance Chapter
Not Enough Flow through
the System
Turn taps on full when using and let run
a few seconds.
Take note if low flow fixtures and adjust
as required.
Remove aerator from the tap spout.
Check if filters are clogged and need
replacement.
Water tastes,
smells or appears
different than
normal NOTE: DO
NOT DRINK UNTIL
CORRECTED
Power to system is off,
generator is not working, or
fuse is blown
Check power connection, and reconnect
as appropriate.
Check operating lights including green
“Ozone Generator” light is lit. If not
contact Aclarus or your representative
immediately and do not consume the
water until corrected.
Malfunctioned or damaged
components
Check all plumbing, tanks, filters, gas-
offs and other system components to
ensure no damage. Also check source
pump, pressure tank or other water
related equipment is functional.
Filter requires replacement
If lights and system appear normal, filter
change may be required.
Source water issue
If system performing normally, conduct
test on source water to ensure safety
before consuming.
Fuse is blown
Check or replace fuses as required
Summary of Contents for AOWT-7
Page 9: ...9 System Components...
Page 10: ...10 NOTE System components and tank may not be exactly as shown...
Page 47: ...47 Appendix Component Specification Sheets Pumps Specifications...
Page 48: ...48...
Page 49: ...49...
Page 50: ...50 Flow Switch Specifications...
Page 51: ...51...
Page 52: ...52 Mazzei Specifications...
Page 53: ...53 Gas Off 1 Specifications...