4.13 Reliability Requirements
4.13.1 Mean Time Before Failure ( MTBF )
30,000 hours with 90% confidence level.(CRT less)
4.13.2 Reference Document
MIL-STD-105D
MIL-HDBK-217E
4.13.3 Electro-Static Discharge ( ESD )
Contact discharge:
Apply 6KV,the set must be auto-recovery
Apply 4KV,the display pattern doesn’t appear noise
Air discharge:
Apply 8KV,be disallow components damage or EEPROM data loss
Apply 6KV,the display pattern does not appear noise.