14
4.8 Internal connectors
All internal connectors for the interconnection of sub assemblies must be distinct in their physical
characteristics or polarization so as to prevent any misconnection which may cause permanent
damage to the display.
4.9 Power Requirements
The display device shall maintain the specified performances in the range described below:
Frequency: 50/60Hz
±
3Hz
Voltage:
90
to
264
Vac
RMS
The following consumption requirements shall be met:
Power consumption: 75W for MPRII & VLMF Yoke
70W for NORMAL Yoke
Current consumption: 1.2 Aac RMS
Note:
Current and power consumption are the maximum values allowed in the voltage ranges describe
above.
4.9.1 Power Management
Table 5: Power Management
NO STATE
STATE
POWER
SAVING
HORIZONTAL
VERTICA
VIDEO
1 ON
PLUSES
PLUSES ACTIVE NONE
2
STAND-BY NO
PLUSES PLUSES
BLANKED
<15W@90
~
240VAC
3
SUSPEND PLUSES
NO
PLUSES
BLANKED
<15W@90
~
240VAC
4
OFF
NO PLUSES
NO PLUSES
BLANKED
<5W@90
~
240VAC
The states of power saving function shall be display by LED indication.
Summary of Contents for AM501
Page 1: ...AM 501 Service Guide 15 inch CRT Monitor ...
Page 4: ......
Page 36: ...32 6 9 Control And Conmect Layout 6 9 1 Main PCB ...
Page 37: ...33 7 0 FUNCTION BLOCK DIAGRAM 7 1 Monitor Portion ...
Page 38: ...34 8 0 POWER SUPPLY PORTION ...
Page 43: ...39 APPENDIX A PARTS LIST ...
Page 55: ...51 APPENDIX B DISPLAY UNTY ASSEMBLY ...
Page 56: ...52 ...
Page 61: ...57 ...
Page 62: ...58 ...
Page 65: ...61 APPENDIX C CRT YOKE ASSEMBLY ...
Page 66: ...62 ...
Page 68: ...64 ...
Page 70: ...66 APPENDIX D P C B A ASSEMBLY ...
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ......