19
4.10.9 Misconvergence
The display must conform to all the following requirements:
Maximum convergence error.
Area
Horizental Direction
Vert. Direction
A
Center field of 195mm diameter
0.30mm 0.30mm
B
Square field of 260 x 195 mm
0.40mm 0.40mm
Table 6 : Misconvergence
The maximum convergence error shall be measured for a white spot or line, and represents the
maximum distance between the energy centers of any two primary colors. The central area is defined as
the area within a circle centered on the CRT faceplate having a diameter equal to the display vertical
dimension.
Figure 14