22
4.11 Functional Performance
4.11.1 Acoustical noise:
The acoustical noise shall be less than 50dB when operating in normal condition, mode change or
power on/off.
4.11.2 Turn off:
Set unit at 20FL of full white screen, then turn off unit, image should disappear smoothly, no persistent
spot and flash.
4.11.3 High voltage discharge:
The arcing due to monitor high voltage discharge shall not cause any damage to devices connected to
the monitor.
4.11.4 Tapping test:
No objectionable intermittence or noise occur while tapping top, left right, rear side of enclosure by a
rubber hammer.