Chapter 9 Redundant Controller
193
The message "Redundant Ctlr Autocfg
Inactive" will appear.
Power-off Controller 1, and then power-
on Controller 2. Set Controller 2 to
"
Autocfg
" as described in the above
steps. Power-off Controller 2.
When the redundant controller function is set to the "Automatic"
setting, the controllers will decide among themselves which will be the
Primary or Secondary controller. If you need to specify a particular
controller as Primary or Secondary, do not set it as "autocfg"; choose
"primary" or "secondary" instead. Refer to the following section.
Redundant Configuration Using Manual Setting
Power-on Controller 1. Make sure
Controller 2 is powered-off.
Press
ENT
for two seconds on the front
panel of Controller 1 to enter the Main
Menu. Use
t
or
s
to navigate through
the menus. Choose "View and Edit
Peripheral Dev..", then press
ENT
.
Choose "Set Peripheral Device Entry",
then press
ENT
.
View and Edit
Peripheral Dev
Set Peripheral
Devices Entry
Redundant Ctlr:
Autocfg Inactive