Chapter 3 Functional Descriptions
19
Manual Rebuild
When a user applies forced-manual rebuild, the controller will first
check whether there is any Local Spare Drive assigned to this logical
drive. If yes, it will automatically start to rebuild.
If there is no Local Spare Drive available, the controller will search for
a Global Spare Drive. If there is a Global Spare Drive, it will
automatically rebuild the logical drive.
User applies
forced-manual
rebuild
Any
Local Spare Drive
assigned to this
logical drive?
Yes
Yes
Rebuild using the
Local Spare Drive
Any
Global Spare Drive
assigned to this
logical drive?
Rebuild using the
Global Spare Drive
No
No
Wait for
manual rebuild
Yes
Has the failed drive
been replaced?
Rebuild using the
replaced drive
No