Chapter 3 Functional Descriptions
13
RAID 5 Striping with Interspersed Parity
Block 1
Block 2
Block 3
Block 4
Block 5
Block 6
Block 7
Block 8
.
.
Logical Drive
Physical Disks
Block 1
Parity (3,4)
Block 6
Block 7
Block 2
Block 3
Parity (5,6)
Block 8
Parity (1,2)
Block 4
Block 5
Parity (7,8)
.
.
.
.
.
.
St non-dedicated Parity
RAID 5
Minimum Disks required
3
Capacity
N-1
Redundancy
Yes
RAID 5 is similar to RAID 3 but the parity data is not stored in one
dedicated hard drive. Parity information is interspersed across the
drive array. In the event of a failure, the controller can
recover/regenerate the lost data of the failed drive from the other
surviving drives.