User’s Guide
198
When One of the Controller Fails...
What will happen when the one of the controllers fails?
When one of the controller fails, the other controller will take over in a
few seconds (about 8 seconds).
The red ATTEN LED will light up, and the
message "Redundant Ctlr Failure
Detected" will appear on the LCD. The
beeper in the controller will start to beep.
The message "Controller ALERT: Redundant Controller Failure
Detected" will also appear on the screen of the terminal interface.
After a controller takes over, it will simultaneously act as both
controllers. If it is the Primary controller that failed, the Secondary
Controller becomes the Primary Controller. If the failed controller is
replaced by a new one later on, the new controller will act as the
Secondary Controller.
Some operating systems will not retry accessing the hard disk drives.
When and How is the Failed Controller Replaced?
Remove the failed controller
after
the take-over of the "working"
controller has been completed.
The new controller has to be pre-configured as the ‘Secondary
Controller’ or in the
"
Autocfg
"
mode.
(Configure the new controller
without the redundant cable and SCSI cables connected.)
Redundant Ctlr
Failure Detected
Summary of Contents for AcerAltos 3102RS
Page 1: ...AcerAltos 3102RS AcerAltos 3102RS Ultra SCSI to Ultra SCSI RAID Controller User s Guide ...
Page 18: ......
Page 20: ......
Page 24: ......
Page 55: ...Chapter 3 Functional Descriptions 37 Drive E now has a capacity just under 1800MB ...
Page 56: ......
Page 64: ...User s Guide 46 Insert RAID Controller Main Board Daughter Board Insert ...
Page 202: ......
Page 218: ......
Page 276: ......
Page 290: ......
Page 296: ...User s Guide G 2 ...