94MS42 Rev.B1 S/W Ver 2.06
2-3
Connecting the chiller (cont.)
UPPER HEAT-EXCHANGER
LOWER HEAT-EXCHANGER
4
12
SOLENOID VALVE, TWO WAY
3
1
D E S C R I P T I O N :
Q'TY
ITEM
2
3
4
5
6
7
8
9
13
14
15
16
17
18
19
20
11
10
SOLENOID COIL
1/2" NPT BALL VALVE, (BLEED VALVE)
1"HOSE ID.BARB-1"NPT MALE PIPE
1"HOSE ID.BARB-3/4"NPT MALE PIPE
1" NPT HEX NIPPLE - MALE
1/2" NPT HEX NIPPLE - MALE
REDUCER NIPPLE - MALE 3/4"-1/2"
NIPPLE, FLOW METER (1"NPT)
1" NPT FEMALE COUPLING
MALE-FEMALE ELBOW 1"NPT
FEMALE TEE 1"NPT
1/2"NPT MALE BRANCH TEE
FEMALE CROSS 3/4"NPT
1/2" NPT FEMALE-FEMALE ELBOW
BRAIDED CLEAR PVC TUBING
HOSE CLAMP FOR 1" HOSE
3
1
5
5
1
8
3
1
2
2
3
3
1
3
2
10FT
6
2
BUSHING - FEMALE TO MALE 1"-1/2"
1
NIPPLE, LONG 1/2"NPTx6"LONG
22
23
2
MOUNTING PLATE
HOSE CLAMP, ø 1.5"-2"
4
24
25
1
1
FLOW METER
TEMPERATURE GAGE
11
9
10
25
22
24
23
TO SYSTEM
FROM
CHILLER
1 TO SECURE FLOW METER (ITEM 24) TO NIPPLE (ITEM 10)
USE HOSE CLAMPS SUPPLIED WITH FLOWMETER.
OUTLET
2 CUT TUBING (ITEM 19) INTO THREE SECTIONS; 24", 41", 43" LENGTHS.
3 APPLY TEFLON TAPE (ITEM 26) TO ALL PIPE THREAD CONNECTION.
4. DO NOT OVERTORQUE FITTINGS.
4
20
19
Bleed Valve
9
12
3
14
5
1
2
43CLM13
11D3382A62
43FIT66
43FIT58
49DCT34
43FIT60
43FIT65
43FIT52
43FIT51
43FIT49
12D3466A07
43FIT46
43FIT57
43FIT44
43FIT43
43FIT42
43FIT41
31S0V09-C240
31S0V09
OLEC PART #
NOTE
3
49THERM01
49FLOW01
4
4
14
13
6
5 ASSEMBLE THE SOLENOID VALVE BRANCHES FIRST BEFORE CONNECTING THEM TO CROSS (ITEM 16).
6. SOME FITTINGS MAY BE ORIENTATED DIFFERENTLY THEN DEPICTED IN THIS SCHEMATIC.
43FIT54
1/2" NPT BRAIDED HOSE, 12" lg.
3
21
43CLM10
49DCT39
FROM
GAUGES
2 PL
49DCT38
1/2" NPT BRAIDED HOSE, 20" lg.
2 PL
26
27
TAPE, TEFLON 1/2" WIDTH
81TAP12
28
LABEL, FLOW DIRECTION (COLD)
15D3587A00
15D3587B00
LABEL, FLOW DIRECTION (HOT)
1
1
4
27
23 2 PL
3 PL
2 PL
5
2 PL
2 PL
8
17
21
21
3 PL
2
8
3 PL
6 PL
21
17
7
22
17
16
15
7
18
7
1
14
11
13
2 PL
20
19
2 PL
28
20
19
RETURN TO
CHILLER
5
5
20
19
2 PL
19
2 PL
20
7. CUSTOMER TO SUPPLY 1" TUBING FOR CONNECTION TO COOLING MODUULE.
29
49DCT41
HOSE INSULATION 1 1/8" X 3/8" WALL
10FT
8. CUT ITEM 29 (HOSE INSUL.) INTO THREE SECTIONS AS STATED IN NOTE No. 2.
INSERT HOSE INSULATION ONTO ITEM 19 (TUBING) BY APPLYING LUBRICANT.
29
8
29
29
DRAIN TO EVAPORATOR
OUT
IN
OUT
IN
OUT
IN
Summary of Contents for AP42CL 8000
Page 1: ...P P AP42CL 8000 Closed Loop High Resolution Printer Service Manual 94MS42 Rev B1 S W 2 06 O ...
Page 12: ...1 6 94MS42 Rev B1 S W Ver 2 06 ...
Page 20: ...2 8 94MS42 Rev B1 S W Ver 2 06 ...
Page 56: ...8 8 94MS42 Rev B1 S W Ver 2 06 ...
Page 84: ...12 6 94MS42 Rev B1 S W Ver 2 06 ...
Page 114: ...13 28 94MS42 Rev B1 S W Ver 2 06 ...
Page 124: ...15 4 94MS42 Rev B1 S W Ver 2 06 ...