94MS42 Rev. B1 S/W Ver. 2.06
4-7
[AUAC]
Press and release the e key until
[AUAC]
appears in the Exposure window.
This places you in the automatic vacuum option.
•
Press the
V
key to cycle the automatic vacuum mode ON or OFF.
•
Press the
0
key twice to exit this mode.
Auto Step Mode
Note:
This feature allows you to run a series of exposures in sequence.
Note:
If Auto Step is selected, the LED over the
U
key will indicate if
the feature is ON or OFF. If ON, press the
V
key to turn it OFF.
•
Press the
P
key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
[SEL_]
Press
1,2,3t 4
in sequence. The Vacuum window will read
[SEL_]
. This places you in the select mode.
•
Press the
Y
key once. The Memory window will read
[Su]
.
[AStP]
Press and release the
e
key until
[AStP]
appears in the Exposure window.
This places you in the autostep option.
•
Press the
V
key to cycle the Auto-Step mode ON or OFF.
•
Press the
0
key twice to exit this mode.
Set Default Vacuum Delay
Note:
This feature is used to provide sufficient vacuum drawdown time
before exposure. The time begins when the frame lid is closed
with the
[AUAC]
turned ON, or when you press the
G
button for
the first time. If you press the
G
button again before the vacuum
delay counts down, the frame will move into the cabinet, but the
exposure will not start until the time is completed.
Note:
This default delay time will be ignored if a delay time other than
0 has been programed into the memory location being displayed.
•
Press the
P
key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
[SEL_]
Press
1,2,3t 4
in sequence. The Vacuum window will read
[SEL_]
. This places you in the select mode.
•
Press the
Y
key once. The Memory window will read
[Su]
.
[dUAC]
Press and release the
e
key until the Exposure window reads
[dUAC]
.
•
Press the
V
key and enter the time you wish the vacuum turned ON
before the exposure begins. The time you selected has now been
programed for all memories.
•
Press the
0
key twice to exit this mode.
Summary of Contents for AP42CL 8000
Page 1: ...P P AP42CL 8000 Closed Loop High Resolution Printer Service Manual 94MS42 Rev B1 S W 2 06 O ...
Page 12: ...1 6 94MS42 Rev B1 S W Ver 2 06 ...
Page 20: ...2 8 94MS42 Rev B1 S W Ver 2 06 ...
Page 56: ...8 8 94MS42 Rev B1 S W Ver 2 06 ...
Page 84: ...12 6 94MS42 Rev B1 S W Ver 2 06 ...
Page 114: ...13 28 94MS42 Rev B1 S W Ver 2 06 ...
Page 124: ...15 4 94MS42 Rev B1 S W Ver 2 06 ...