4-8
94MS42 Rev. B1 S/W Ver. 2.06
Tray Mode
!
C
The default tray speed is set at the factory to 5 seconds. OLEC does not
recommend changing this setting without consulting the
OLEC factory. Damage to the transport can occur.
•
Press the
P
key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
[SEL_]
Press
1,2,3t 4
in sequence. The Vacuum window will read
[SEL_]
. This places you in the select mode.
•
Press the
Y
key once. The Memory window will read
[Su]
.
[trAY]
Press the
e
key until
[trAY]
appears in the Exposure window.
•
Press the
V
key once. The Vacuum window will read
[----]
and the
Exposure window will read
[codE]
. If lock mode was turned ON, enter
your code now, then press the
V
key, (If the lock code has never been
changed
section 4.3
, the default code is 000).
•
Enter the time you wish to have the tray speed set for. For example, for a
5.0 second travel time, press
5
,
0
and then press the
V
key again the
Memory window and Exposure window will return to normal brightness.
•
Press the
0
key twice to exit this mode.
Type Mode
!
C
The type has been set at the factory and should not be changed.
Proper operation of the unit will be affected if changed.
•
Press the
P
key on the integrator to power up the light, the front remote
switches, and the exposure unit's computer system.
[SEL_]
Press
1,2,3t 4
in sequence. The Vacuum window will read
[SEL_]
. This places you in the select mode.
•
Press the
Y
key once. The Memory window will read
[Su]
.
[tYPE]
Press the
e
key until
[tYPE]
appears in the exposure window. This places
you in the System Type option.
•
Press the
V
key once. The Vacuum window will read
[----]
and the
Exposure window will read
[codE]
. If lock mode was turned ON, enter
your code now, then press the
V
key, (If the lock code has never been
changed, the default code is 000).
[AP30]
Press the V key to cycle the Vacuum window to read [AP30]. This setting
applies to both the AP30 5kW and AP30 8kW, air conditioned and closed
loop models.
•
Press the
0
key twice to exit this mode.
Summary of Contents for AP42CL 8000
Page 1: ...P P AP42CL 8000 Closed Loop High Resolution Printer Service Manual 94MS42 Rev B1 S W 2 06 O ...
Page 12: ...1 6 94MS42 Rev B1 S W Ver 2 06 ...
Page 20: ...2 8 94MS42 Rev B1 S W Ver 2 06 ...
Page 56: ...8 8 94MS42 Rev B1 S W Ver 2 06 ...
Page 84: ...12 6 94MS42 Rev B1 S W Ver 2 06 ...
Page 114: ...13 28 94MS42 Rev B1 S W Ver 2 06 ...
Page 124: ...15 4 94MS42 Rev B1 S W Ver 2 06 ...