Schedule 40 

1.5” conduit

XTR cabling

IMPORTANT CABLING CONSIDERATIONS

During installation, protection of the XTR cabling must always be fully 
considered:

 

Wherever possible, cable runs should be positioned to make them beyond 
normal reach within any installation.

 

For long cable runs, external runs and in areas where public contact and/or 
accidental damage is possible, the XTR cabling should be contained within 
protective conduit. Minimum spec: Schedule 40, 1.5” (ID: Ø1.61”, OD: Ø1.74”).

 

Additional power cabling: Where power feeds require the use of non-XTR 
cabling, the power cores should be 14 AWG minimum.

 

Additional DMX control cabling: For initial control runs leading to the XTR 
cabling, these are recommended: 

 

Indoor exposed or inside conduit above grade: Belden 9842

 

Indoor plenum: Belden 82842

 

Outdoor exposed, direct burial, or inside conduit below grade:  
Belden 3107DB

 

Please consult and adhere to all relevant local codes.

RUN LENGTHS - OVERALL MAXIMUM

In addition to remaining within the maximum permitted length of 

fixtures

 in a single 

run (as discussed on page 9), you also need to adhere to the working limits for the 
overall length of the 

whole installation

, ie the total length fixtures in the run 

plus

 all their 

additional feed and link cabling, as listed below. 

Note: These limits are imposed only by the power characteristics. The length of the DMX control 
feed to the first XTR fixture could be up to the usual DMX standard limit (3,900 feet/1200m) with 
appropriate cable choice (see ‘Important cabling considerations’ below).

 

Supply 

Maximum overall run length 

 

voltage 

(fixtures plus all extra cabling)

 

100/120VAC (10A max) 

200’ (61m)

 

230/277VAC (10A max) 

400’ (121m)

 

380VDC (XTR Driver) 

800’ (243m)

IMPORTANT: Ensure the voltage drop across the entire run does not exceed 9%.

Summary of Contents for Linear XTR

Page 1: ...User guide Linear XTR...

Page 2: ......

Page 3: ...overall maximum 10 Important cabling considerations 10 Optional AJBOX1 conduit connections 11 Interconnecting 12 Connecting units at angles up to 60 13 Control 14 DMX control considerations 15 Tips fo...

Page 4: ...r configuration DALI and 0 10V control inputs can also be used when optional converters are employed SAFETY When fixtures are mounted off ground ensure they are securely fitted to an appropriate mount...

Page 5: ...1 4 121cm XTRLV4 The 4 option consists of four 1 louvers which are used together Glare shield 1 30cm XTRGS1 4 121cm XTRGS4 Feed cables incl terminator end cap 10 3m XTRFC10 50 15m XTRFC50 100 30m XTRF...

Page 6: ...l fixture bolts and washers 1 30cm XTREB1 2 60cm XTREB2 3 91cm XTREB3 Aluminum body Wall mounting screws not included OPTIONAL ACCESSORIES CONTINUED IP66 junction box incl outlet cable gland AJBOX1 DM...

Page 7: ...hat the chosen angle is retained without the need for tools Tilt guage TO MOUNT THE FIXTURE 1 Where necessary prepare four pilot holes in the mounting surface which align with the swivel mount base sl...

Page 8: ...ment to the mounting surface Suitably sized wall screws should be chosen based on the mounting surface TO MOUNT THE FIXTURE 1 Rotate both swivel mounts all the way over to allow access to the slots on...

Page 9: ...roove running along the underside of the fixture 2 Slide in the glare shield until it is fully inserted along the fixture Grooves running along each side Louver FITTING AN OPTIONAL LOUVER Optional lou...

Page 10: ...e that the connector is fully locked onto the socket Any unused output ports must have their cover cap securely fixed in place Do not exceed the stated maximum fixtures in a daisy chain see page 9 At...

Page 11: ...100VAC 230VAC XTR Driver XTR Driver draw 277VAC 4000 8000 EO 5W ft 200 400 700 2x 700 SO 12W ft 100 200 300 2x 300 FLEXIBLE POWER OPTIONS Linear XTR fixtures support two different power options XTR Dr...

Page 12: ...door plenum Belden 82842 Outdoor exposed direct burial or inside conduit below grade Belden 3107DB Please consult and adhere to all relevant local codes RUN LENGTHS OVERALL MAXIMUM In addition to rema...

Page 13: ...further details please see Page 8 for wire colors Acclaim Lighting AJBOX1 user guide Acclaim Lighting XTR Driver user guide WARNING HIGH VOLTAGE This device can use high voltages up to 400VDC which c...

Page 14: ...socket and plug and then push them together so that the blue lock ring clicks fully into place As each connection is made ensure that the connector is fully locked onto the socket Any unused output po...

Page 15: ...ITS AT ANGLES UP TO 60 It is possible to connect neighboring fixtures at angles up to 60 without the use of separate link cables IMPORTANT Do not exceed angles of 60 between fixtures to avoid placing...

Page 16: ...and 8000 units can accept DMX 0 10V or DALI control inputs directly The latter two methods are converted within the driver before being transmitted as DMX within the consolidated output together with...

Page 17: ...end cap will correctly terminate the DMX signal and will also safely seal off the power bus The DMX cable connected to the feed cable should be suited for RS 485 data transmission and have a characte...

Page 18: ...passage of conditioned and isolated signals is fully bi directional POWER Every XTR fixture conditions its own power using a high efficiency internal switched mode power supply A well known feature of...

Page 19: ...TO ADDRESS OK CANCEL 001 001 4 On the XMT 350 press the right arrow button to change to the PATCH tab 5 If necessary use the up down buttons to choose an alternative fixture 6 Press the button to set...

Page 20: ...ESSING The actual alignment of Linear XTR fixture cells to DMX addressing is determined by the base address see page 17 and for 4 models also the chosen cell mode personality For a fixture assigned wi...

Page 21: ...es and after a short while the XMT 350 will display a list of all located fixtures The fixture highlighted in the list will flash its emitters to identify itself 3 If necessary use the up down buttons...

Page 22: ...the fixture s and the XMT 350 3 On the XMT 350 press the MODE button then use the arrow buttons to highlight the SEND function and press the button to select 4 Use the arrow buttons to determine the D...

Page 23: ...an RDM tool to perform an emitter test Check that the DMX address set within the fixture matches that being output by the controlling source device Check the DMX output near to the source to confirm...

Page 24: ...Lengths 1 305mm or 4 1220mm Maximum lengths in series Up to 700 213m via XTR Driver 4000 8000 see page 9 Operating voltage 100 277VAC 50 60Hz direct or 380VDC via XTR Driver 4000 8000 Power consumptio...

Page 25: ...23 www acclaimlighting com DIMENSIONS...

Page 26: ...24 www acclaimlighting com OPTIONAL EXTENDER ARM...

Page 27: ...rd party items not manufactures by Acclaim lighting During the period specified above Acclaim Lighting will replace defective parts at its expense and will absorb all expenses for warranty service and...

Page 28: ...www acclaimlighting com...

Reviews: