9
www.acclaimlighting.com
RUN LENGTHS - FIXTURE MAXIMUM
The maximum number of fixtures that can be driven in a single run is determined by the
supply voltage and the collective power requirements for the fixtures. The maximum total
lengths listed here can be formed from any combination of 1’ or 4’ fixtures. Fixtures with
differing LED emitter specifications can be mixed freely as they all adhere to the same power
specifications
(see also “Run lengths - overall maximum” on page 10)
.
Model
Power
100VAC
230VAC
XTR Driver
XTR Driver
draw
277VAC
4000 8000
EO
(5W/ft)
200’
400’
700’
2x 700’
SO
(12W/ft)
100’
200’
300’
2x 300’
FLEXIBLE POWER OPTIONS
Linear XTR fixtures support two different power options:
XTR Driver supply
An optional XTR Driver 4000 or
XTR Driver 8000 can be used to
create a special high voltage supply
(380VDC) in order to achieve greatly
increased fixture run lengths.
Standard mains supply
Using a feed cable, one or
more Linear XTR fixtures can be
powered directly from a standard
mains supply, ranging from 100
to 277VAC (50/60Hz).
Note:
Linear XTR fixtures
can use either power
method without any
reconfiguration; voltage
levels are automatically
detected.
Optional
AJBOX1
enclosure