TROUBLESHOOTING
NO LIGHT OUTPUT IS VISIBLE WHEN EXPECTED
•
Check that power is correctly applied to the fixture and that there is no damage to the
power input cord.
•
Use an RDM tool to perform an emitter test.
•
Check that the DMX address set within the fixture matches that being output by the
controlling source device.
•
Check the DMX output near to the source to confirm a valid signal is being originated.
•
Check that the DMX + (hot) and DMX - (cold) lines have not been crossed.
•
[Fixtures with white emitters only] If no control protocol is present, white light fixtures will
default to full on.