38
Declarations of compliance
6. DECLARATIONS OF COMPLIANCE
for the ESEZ60500 Alarm Panel System
Standards with which the alarm panel claims compliance
Security level: EN50131-1 Grade 2, VSÖ class GS-N
Environmental class II
If the alarm panel has been installed correctly, the Secoris will be compliant with EN50131 Grade 2
or VSÖ class GS-N.
The Secoris is compliant with EN50131-1 and EN50130-5 environmental class II.
Power supply is compliant with EN50131-1:2006+A1 2009 Section 9 and EN50131-6 if the alarm panel has
been installed correctly.
The alarm transmission system (integrated SP2 [ATS2] communicator) is compliant with EN50136-1:2012 as an
SP2 (ATS2) communicator.
At Grade 2 the integrated SP2 (ATS2) communicator provides a compliant communicator for the Secoris on
the condition that
a) it is installed as specified in the installation instructions
b) the connected PSTN, LAN and GSM work normally
c) the alarm receiving centre has the right equipment
The ESMO60010 PSTN module can be used as a supplementary communicator for Grade 2.
The alarm panel supports options A, B and C for grade 2 as given in Table 10 in EN50131-1:2006+A1:2009.
If the installer selects a non-compliant configuration the compliance label must be removed or corrected.