7
all the memories in a week will be cleared completely.
l
Program browse
It is necessary to browse the programs already compiled to prevent mistaking
after the programming is completed. The browse method is as follows: Enter the
timer program
interface, adjust the
week
entry parameters and use them for locating the concrete date for browsing; It
is available to browse in real-time all the programs of that day by adjusting the
ordinal number
entry
parameter.
l
Running
The inner programs will be started and run after the equipment is normally powered on.
l
Other functions
1.
Data protection function
The programming will not effect the normal operation of other programs;
The programs compiled will run right away and have memory for power off; Including the memory for
the power off during the deleting and duplicating process and the memory for the time power off.
2.
Intelligent main interface
The backlight indicator is lit manually, or is lit programmable and
automatically, and it is distinguished automatically in 1 minute when there is no operation; It is
distinguished automatically in 5 minutes when there is no operation for other interfaces.
3.
Main power logic output
MAIN 1 and 2
will be turned on automatically and the interface of
TIMER OUT
will be triggering the output alarm signal when any of
CH 1, 2, 3 and 4
channels in the
program is turned on;
MAIN 1 and 2
will be turned off when
CH 1, 2, 3 and 4
channels are all turned
off; The alarm output signal of
TIMER OUT
interface will be stopped at this time.