EN - 10
BAL.0361.0 • 2021-02-25
3 Product description
iCAT mini
The load data was determined under standard conditions, at low to medium heat of reflection,
free air circulation and an ambient temperature of approx. 28 °C. When used under more
strenuous conditions, the load data must be reduced by 10–20%.
3.2 Abbreviations
Type
Type
of
cool-
ing
Load
1
DC
Wire
Gas flow
rate
Cooling data
Cooling
capacity
Flow
Flow
pressure
CO
2
M21
Min.
Min.
Min. Max.
A
A
%
mm
L/min
W
L/min
bar
bar
ABIROB
®
G350
Air
350 300 100 0.8–1.2
Approx.
20
800
Approx.
20
-
-
ABIROB
®
G360
Air
360 290 100 0.8–1.6
Approx.
20
800
Approx.
20
-
-
ABIROB
®
G500
Air
500 400 100 0.8–1.6
Approx.
20
800
Approx.
30
-
-
ABIROB
®
W300
Liquid 330 300 100 0.8–1.2
Approx.
20
800
1.25
1.5
3.5
ABIROB
®
W500
Liquid 550 500 100 0.8–1.6
Approx.
20
800
1.25
1.5
3.5
ABIROB
®
W600
Liquid 600 550 100 0.8–1.6
Approx.
20
800
1.25
1.5
3.5
Tab. 8
Product-specific welding torch data (EN 60 974-7) in connection with
iCAT mini
1For pulse arcs, the load data is reduced by up to 35%.
ABIROB
®
G
Automatic welding torch, air-cooled
ABIROB
®
W
Automatic welding torch, liquid-cooled
Tab. 9
Abbreviations
Summary of Contents for iCAT mini
Page 4: ...DE 4 BAL 0361 0 2021 02 25 1 Identifikation iCAT mini 1 2 EU Konformitätserklärung ...
Page 39: ...BAL 0361 0 2021 02 25 EN 5 iCAT mini 1 Identification 1 2 EU declaration of conformity ...
Page 73: ...BAL 0361 0 2021 02 25 ZH 5 iCAT mini 1 标识 1 2 欧盟符合性声明 ...
Page 109: ...BAL 0361 0 2021 02 25 JA 5 iCAT mini 1 概要 1 2 EU 適合宣言 ...
Page 146: ...BAL 0361 0 2021 02 25 Notizen Notes 记录 メモ iCAT mini Notizen Notes 记录 メモ ...
Page 147: ...BAL 0361 0 2021 02 25 iCAT mini Notizen Notes 记录 メモ Notizen Notes 记录 メモ ...